Overhead Power Transmission XLPE/PVC Insulation Aluminum Conductor ABC Cable Meets International IEC Standard IEC 60502-1, Tnb Specification, and HD 626 S1

Model NO.
ABC CABLE
Wire Core Material
Aluminum
Certification
ISO, CCC, CE
Model
ABC Cable
Brand
Asian Sun
Transport Package
Wooden Drum/Wooden Steel Drum/Rolls
Specification
as the costumer request
Trademark
Asian Sun
Origin
Henan, China
HS Code
8544492100
Production Capacity
50000meters Per Day
Reference Price
Please contact us for quote

Product Description

Overhead Power Transmission XLPE/PVC insulation Aluminum conductor ABC cable meets International IEC standard IEC 60502-1, TNB Specification, and HD 626 S1

Product Description
Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.
 LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.
It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.
This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.
Detailed Photos

 

 

Overhead Power Transmission XLPE/PVC Insulation Aluminum Conductor ABC Cable Meets International IEC Standard IEC 60502-1, Tnb Specification, and HD 626 S1

Overhead Power Transmission XLPE/PVC Insulation Aluminum Conductor ABC Cable Meets International IEC Standard IEC 60502-1, Tnb Specification, and HD 626 S1

Overhead Power Transmission XLPE/PVC Insulation Aluminum Conductor ABC Cable Meets International IEC Standard IEC 60502-1, Tnb Specification, and HD 626 S1

Product Parameters

 

ABC CABLE DATA SHEET
Executive Standard:ASTM          
    Bare neutral Messenger Phase conductor            
Code Word AWG or kcmil AAAC Rated Strength AAC insulation thickness (m m ) Weight (kg/km )          
    s trading and w ires dia(mm ) (lbs ) strading and wires dia(mm )            
Bay 3*6AWG+ 1*30.58 7/ 1.68 1110 1/4.11 1.14 207          
French Coach 3*6AWG+ 1*30.58 7/ 1.68 1110 7/ 1.56 1.14 2 13          
German Coach 3*4AWG+ 1*48.69 7/2. 12 1760 1/5.1 9 1.14 309          
Arabian 3*4AWG+ 1*48.69 7/2. 12 1760 7/ 1.96 1.14 316          
Belgian 3*2AWG+ 1*77.47 7/2.67 2800 7/2.47 1.14 476          
Shet land 3*1/0AWG+ 1*123.3 7/3.37 4460 19/ 1.89 1.52 768          
Thoroughbred 3*2/0AWG+ 1*155.4 7/3.78 5390 19/2.13 1.52 945          
Trotter 3*2/0AWG+ 1*195.7 7/4.25 6790 19/2.39 1.52 1166          
Walking 3*4/0AWG+ 1*246.9 7/4.77 8560 19/2.68 1.52 1442          
                       
Executive Standard:NFC        
                       
  Nom inal     Average diameter of   Average                  insulation thickness        
  cross-section aera Wire number in Conductor Max resistance at 20 conductor Rated Strength        
Description mm 2 No. Ohm /k m Min(m m ) Max(m m ) KN m m        
PHASE, NEUTRAL,and PUBLIC HIGHTING 16 7 1.91 4.6 5.1 1.9 1.2        
25 7 1.2 5.8 6.3   1.4        
35 7 0.868 6.8 7.3   1.6        
50 7 0.641 7.9 8.4   1.6        
70 12 0.443 9.7 10.2   1.8        
95 19 0.32 11 12   1.8        
120 19 0.253 12 13.1   1.8        
150 19 0.206 13.9 15   1.7        
PORTER 54.6 7 0.63 9.2 9.6   1.6        
70 7 0.5 10 10.2   1.5        
95 19 0.343 12.2 12.9 27.5 1.6        
                       
Executive Standard:IEC1        
Phase Phase Phase   Max. D.C.        
AAC+UV-XLPE Compact Conductor UV-XLPE Insulation Approx.Overall Diam eter Res is tance of Conductor at 20 ºC        
No.X Norm al Cross Section of Cores No.of Al Wires Overall Diameter Normal Thickness Min. Diameter            
No. X m m 2 - m m m m m m m m m m ohm /k m        
1 X 10 7/1.35 4.05 1 0.8 6.05 6.05 3.08        
1 X 16 7/1.70 4.8 1.2 0.98 7.2 7.2 1.91        
1 X 25 7/2.24 6 1.2 0.98 8.4 8.4 1.2        
1 X 35 7/2.58 7 1.4 1.16 9.8 9.8 0.868        
1 X 50 7/3.00 8.3 1.4 1.16 11.1 11.1 0.641        
1 X 70 19/2.15 9.8 1.4 1.16 12.6 12.6 0.443        
1 X 95 19/2.58 11.6 1.6 1.34 14.8 14.8 0.32        
1 X 120 18/3.00 13 1.6 1.34 16.2 16.2 0.253        
1 X 150 30/2.58 14.6 1.8 1.52 18.2 18.2 0.206        
1 X 185 36/2.58 16.2 2 1.7 20.2 20.2 0.164        
1 X 240 36/3.00 18.4 2.2 1.88 22.8 22.8 0.125        
2 X 10 7/1.35 4.05 1 0.8 6.05 12.1 3.08        
2 X 16 7/1.70 4.8 1.2 0.98 7.2 14.4 1.91        
2 X 25 7/2.24 6 1.2 0.98 8.4 16.8 1.2        
2 X 35 7/2.58 7 1.4 1.16 9.8 19.6 0.868        
2 X 50 7/3.00 8.3 1.4 1.16 11.1 22.2 0.641        
2 X 70 19/2.15 9.8 1.4 1.16 12.6 25.2 0.443        
2 X 95 19/2.58 11.6 1.6 1.34 14.8 29.6 0.32        
2 X 120 18/3.00 13 1.6 1.34 16.2 32.4 0.253        
2 X 150 30/2.58 14.6 1.8 1.52 18.2 36.4 0.206        
2 X 185 36/2.58 16.2 2 1.7 20.2 40.4 0.164        
2 X 240 36/3.00 18.4 2.2 1.88 22.8 45.6 0.125        
3 X 10 7/1.35 4.05 1 0.8 6.05 13.07 3.08        
3 X 16 7/1.70 4.8 1.2 0.98 7.2 15.55 1.91        
3 X 25 7/2.24 6 1.2 0.98 8.4 18.14 1.2        
3 X 35 7/2.58 7 1.4 1.16 9.8 21.17 0.868        
3 X 50 7/3.00 8.3 1.4 1.16 11.1 23.98 0.641        
3 X 70 19/2.15 9.8 1.4 1.16 12.6 27.22 0.443        
3 X 95 19/2.58 11.6 1.6 1.34 14.8 31.97 0.32        
3 X 120 18/3.00 13 1.6 1.34 16.2 34.99 0.253        
3 X 150 30/2.58 14.6 1.8 1.52 18.2 39.31 0.206        
3 X 185 36/2.58 16.2 2 1.7 20.2 43.63 0.164        
3 X 240 36/3.00 18.4 2.2 1.88 22.8 49.25 0.125        
4 X 10 7/1.35 4.05 1 0.8 6.05 14.64 3.08        
4 X 16 7/1.70 4.8 1.2 0.98 7.2 17.42 1.91        
4 X 25 7/2.24 6 1.2 0.98 8.4 20.33 1.2        
4 X 35 7/2.58 7 1.4 1.16 9.8 23.72 0.868        
4 X 50 7/3.00 8.3 1.4 1.16 11.1 26.86 0.641        
4 X 70 19/2.15 9.8 1.4 1.16 12.6 30.49 0.443        
4 X 95 19/2.58 11.6 1.6 1.34 14.8 35.82 0.32        
4 X 120 18/3.00 13 1.6 1.34 16.2 39.2 0.253        
4 X 150 30/2.58 14.6 1.8 1.52 18.2 44.04 0.206        
4 X 185 36/2.58 16.2 2 1.7 20.2 48.88 0.164        
4 X 240 36/3.00 18.4 2.2 1.88 22.8 55.18 0.125        
                       
Executive Standard:IEC2      
Phase Neutral Phase Neutral   Max. D.C.    
AAC+UV-XLPE AAAC Compact Conductor UV-XLPE Ins ulation Conductor   Resistance of Conductor at 20 ºC    
No.X Norm al Cr os s No.X Norm al Cross           Approx. Overall Diam eter        
Section of Cores Section of Cores No.of Al.Wire Overall Dia. Norm al Thick ness Min. No./Dia. of Al Alloy Wire   Phase Neutral    
No. X m m 2 No. X m m 2 - m m m m Min. No./m m m m ohm /k m ohm /k m    
1 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 12.3 1.91 2.217    
1 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 14.7 1.2 1.393    
1 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 17.3 0.868 1.007    
1 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 20.1 0.641 0.744    
1 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 23.1 0.443 0.514    
1 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 27.3 0.32 0.371    
1 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 30.2 0.253 0.294    
1 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 33.95 0.206 0.239    
1 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 37.7 0.164 0.19    
1 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 43.05 0.125 0.145    
2 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 14.04 1.91 2.217    
2 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 16.63 1.2 1.393    
2 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 19.51 0.868 1.007    
2 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 22.46 0.641 0.744    
2 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 25.7 0.443 0.514    
2 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 30.31 0.32 0.371    
2 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 33.41 0.253 0.294    
2 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 37.55 0.206 0.239    
2 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 41.69 0.164 0.19    
2 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 47.41 0.125 0.145    
3 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 16.15 1.91 2.217    
3 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 19.06 1.2 1.393    
3 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 22.32 0.868 1.007    
3 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 25.59 0.641 0.744    
3 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 29.22 0.443 0.514    
3 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 34.42 0.32 0.371    
3 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 37.87 0.253 0.294    
3 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 42.56 0.206 0.239    
3 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 47.25 0.164 0.19    
3 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 53.63 0.125 0.145    
                       
Executive Standard:IEC3                      
Phase Neutral Service Connection Phase Neutral Service Connection  
Approx. Overall
Diameter of Bundled Cable
AAC+UV-XLPE AAAC+UV-XLPE AAC+UV-XLPE Conductor UV-XLPE Conductor UV-XLPE Compact Conductor UV-XLPE  
No.X Normal Cross No.X Normal Cross No.X Normal Cross     Normal   Normal     Normal  
Section of Cores Section of Cores Section of Cores No. of Al. Wire Overall Dia. No./Dia. of Al. Wire No. of Al. Wire Overall Dia.
                       
Thickness Thickness Thickness
No. X mm2 No. X mm2 No. X mm2 - mm mm mm mm No./mm mm mm mm
3 X 16 1 X 50 1 X 16 7/1.70 4.8 1.2 7/3.0 1.4 7/1.70 4.8 1.2 26.2
3 X 25 1 X 50 1 X 16 7/2.24 6 1.2 7/3.0 1.4 7/1.70 4.8 1.2 28.6
3 X 35 1 X 50 1 X 16 7/2.58 7 1.4 7/3.0 1.4 7/1.70 4.8 1.2 31.4
3 X 50 1 X 50 1 X 16 7/3.00 8.3 1.4 7/3.0 1.4 7/1.70 4.8 1.2 34
3 X 70 1 X 50 1 X 16 19/2.15 9.8 1.4 7/3.0 1.4 7/1.70 4.8 1.2 37
3 X 95 1 X 50 1 X 16 19/2.58 11.6 1.6 7/3.0 1.4 7/1.70 4.8 1.2 41.4
3 X 120 1 X 50 1 X 16 18/3.00 13 1.6 7/3.0 1.4 7/1.70 4.8 1.2 44.2
3 X 16 1 X 50 2 X 16 7/1.70 4.8 1.2 7/3.0 1.4 7/1.70 4.8 1.2 26.2
3 X 25 1 X 50 2 X 16 7/2.24 6 1.2 7/3.0 1.4 7/1.70 4.8 1.2 28.6
3 X 35 1 X 50 2 X 16 7/2.58 7 1.4 7/3.0 1.4 7/1.70 4.8 1.2 31.4
3 X 50 1 X 50 2 X 16 7/3.00 8.3 1.4 7/3.0 1.4 7/1.70 4.8 1.2 34
3 X 70 1 X 50 2 X 16 19/2.15 9.8 1.4 7/3.0 1.4 7/1.70 4.8 1.2 37
3 X 95 1 X 50 2 X 16 19/2.58 11.6 1.6 7/3.0 1.4 7/1.70 4.8 1.2 41.4
3 X 120 1 X 50 2 X 16 18/3.00 13 1.6 7/3.0 1.4 7/1.70 4.8 1.2 44.2
 
Certifications

Overhead Power Transmission XLPE/PVC Insulation Aluminum Conductor ABC Cable Meets International IEC Standard IEC 60502-1, Tnb Specification, and HD 626 S1

Packaging & Shipping

wooden drums with diameter 1.1m, 1.2m, 1.6m, 1.8m and 2.2m; 

20GP, 40GP and 40HQ containers

Overhead Power Transmission XLPE/PVC Insulation Aluminum Conductor ABC Cable Meets International IEC Standard IEC 60502-1, Tnb Specification, and HD 626 S1

Company Profile

Luoyang Asian Sun Wire & Cable Co., Ltd., founded in 2016 and located in the Industrial Cluster area of Yichuan,Luoyang, covers an area of more than 60,000 square meters, is an independent export-oriented enterprise, professionally engaged in design, manufacturing and trade. We specialize in the production and supply Aluminum rod, Aluminum stranded cable(AAC, AAAC,ACSR,ACAR,ACSS/AW,AACSR,ACSR/AW,AACSR/AW ACS,GWS) Overhead insulated cable(LV,MV ABC Overhead Wire ),power cable, solar cable, building cable and so on, OEM also accepted. 
The expanded business of our Group includes industry, Hardware, electromagnetically device, new energy equipment and auxiliary products, as well as the manufacturing and trade of municipal rescue supporting materials.
Luoyang Asian Sun wire & cable has over 200 employees, five modern management workshops and 37 advanced production equipments, Aluminum rod annual output of 200, 000 tons and Cable products annual sales over 500 million.

Overhead Power Transmission XLPE/PVC Insulation Aluminum Conductor ABC Cable Meets International IEC Standard IEC 60502-1, Tnb Specification, and HD 626 S1 Overhead Power Transmission XLPE/PVC Insulation Aluminum Conductor ABC Cable Meets International IEC Standard IEC 60502-1, Tnb Specification, and HD 626 S1 Overhead Power Transmission XLPE/PVC Insulation Aluminum Conductor ABC Cable Meets International IEC Standard IEC 60502-1, Tnb Specification, and HD 626 S1

 

Relative products


FAQ

Q1. Are you a manufacturer?
Yes, we are a manufacturer own factory with almost 20 years experiences.
Q2. What are your main products?
Main products including: ACSR, AAC, AAAC ,ACAR,ACSS,ACSS/TW,ACCC,ACSR/AW,ACS ,GSW, Aerial Bundled Cable(Low/Medium Voltage ABC Overhead Wire ),Power Cable,Copper Alloy Wire for Electrical Railway System
Q3. Which countries and regions have your products been exported to ?
Asia, South America, North America, Europe, Africa, Oceania,including: Peru,Colombia, Chile,Korea, America, Philippines, Vietnam,Singapore, Australia,Dominica,Kenya,Poland,Pakistan,Rwanda,Brazil,Myanmar,Zambia, Congo,Ecuador,Lesotho,Bolivia,Thailand ,Germany,Angola,Yemen,India,Netherlands,Benin,Maldives,Canada,Honduras,Albania,Burundi,Paraguay , Sri Lanka,New Zealand,Bahrain,Costa Rica,Trinidad and Tobago,Guyana, Nicaragua,Mongolia,Haiti,Ghana,Macedonia etc.
Q4. Is the quality of your products guaranteed?
Yes,the quality of our products is highly guaranteed. The products are ISO 9001 ,ISO 14001,OHSAS 18001 certificated. Our workshops are equipped with advanced production and inspection equipment and the products strictly according to international standards or customers' requirements. We do 100% inspection for every batch of semi-finished and finished products.
Q5. What's the package of products ?
The package is usually wooden drums ,steel drums,steel-wooden drums or according to customers' requirement.
Q6. How can I get samples?
Please notify the detailed information of sample you need. If we don't have the exact model, please consider whether the similar model is OK for you. we provide the free samples for inspection while freight is charged.
Q7. What is our payment terms ?
We can accept the following payment terms: T/T, L/C, O/A

 

PNEUTEC.IT, 2023