| GA series High frequency inverter data sheet | ||||
| Model | GA3024ML | GA3024MH | GA5048MH | |
| Input | Phase | L+N+PE | ||
| Nominal Voltage | 208/220/230/240VAC | |||
| Voltage Range | 154-264VAC±3V ( Normal Mode) 185-264VAC±3V ( UPS Mode ) | |||
| Frequency Range | 50Hz/60Hz(Adaptive) | |||
| Output | Rated Power | 3000W | 3000W | 5000W |
| Output Voltage(AC) | 208/220/230/240VAC±5% | |||
| Output Frequency | 50/60Hz±0.1% | |||
| Waveform | Pure sine wave | |||
| Transfer Time( Optional) | 10ms for computer , 20ms for home appliances | |||
| Peak power | 6000VA | 6000VA | 10000VA | |
| Overload |
Battery Mode
:
1min@102%~110% Load 10s@110%~130% Load 3s@130%~150% Load 200ms@>150% Load |
|||
| Peak efficiency (battery mode) | >94% | >94% | >94% | |
| Battery | Rated voltage | 24Vdc | 24Vdc | 48Vdc |
| Constant voltage charging voltage (Optional) | 28.2Vdc | 28.2Vdc | 56.4Vdc | |
| Floating charge voltage (Optional) | 27Vdc | 27Vdc | 54Vdc | |
| charger | PV charging method | MPPT | MPPT | MPPT |
| PV max input power | 1500W | 3500W | 5500W | |
| MPPT tracking range | 30~115Vdc | 120~430Vdc | 120~430Vdc | |
| Max PV input voltage | 145Vdc | 450Vdc | 450Vdc | |
| Max PV charging current | 60A | 60A | 80A | |
| Max AC charging current | 60A | 60A | 80A | |
| Max charging current | 120A | 60A | 80A | |
| Display | LCD display | Operating mode/load/input/output, etc. | ||
| Communication port | RS232 | 5PIN/Pitch2.0mm, baud rate 2400 | ||
| Expansion & configuration port |
2×5PIN/Pitch2.54mm, lithium battery BMS communication card,
WIFI card, dry contact card, etc. |
|||
| Parallel interface | No | Yes | ||
| Environmental parameters | Operating environment temperature | 0~40 ºC | ||
| Operating environment humidity | 20%~95% ( Non condensing ) | |||
| Storage temperature | -15~60 ºC | |||
| Altitude |
The altitude should not exceed 1000m, derating above 1000m,
up to 4000m, refer to IEC62040 |
|||
| noise | ≤50db | |||
| Certifications | EN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1 | |||
Place of Origin: