Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan

Model NO.
FBCDZ(B)-10
Exported to
All Countries
Warranty
18 Months
Application
Metallurgy Invented The Explosion-Proof Patent Tec
Provide
From Direct Factory
Company
Customized Manufacturing
Shipping Term
EXW, Fob and CIF
Speed
490-1450 Rpm
Use
Coal Mines
Power
2*55~1250 Kw
Pressure
860-6921 PA
Air Volume
59.5-187.9~182.6-462.1 M3/S
Transport Package
Wooden Box/Steel Frame
Specification
Have many sizes,Can provide according to your need
Trademark
Zhi Feng
Origin
China
HS Code
8414599099
Production Capacity
5000
Reference Price
$ 360.00 - 1,800.00

Product Description



Introduction

To meet the needs of coal mines, the mine energy-saving promotion station of the Ministry of Metallurgy invented the explosion-proof patent technology of the e xtraction t ype   main fan of the coal mine s . The materials used in the machine have passed the friction spark test of the Test Center of China Coal Research Institute Chongqing Branch   and achieved the explosion-proof requirements.   The explosion-proof performance of the whole machine has passed the explosion-proof inspection of the China National Quality Supervision and Test Centre for Explosion-Protected Electrical Products. It i ntroduce s  the FBCDZ (formerly BDK62) series  of coal mine ground explosion-proof extraction-type   counter-rotating axial flow ventilator , which   has better performance, more specifications, and larger coverage. The product is subject to the standard s of  Q / ZFJ001-2004 the T echnical C onditions of the FBCDZ (formerly BDK62) S eries  of C oal M ine G round E xplosion-proof E xtraction T ype C ounter-rotating  A xial F low ventilator .


Characteristics
1. To meet the resistance requirements of the coal mine ventilation network and ensure the efficiency of the ventilator , the machine adopts the counter-rotating structure, that is, two sets of the same model of fan s  are connected, and the rotation direction of the impeller s   of the two machines is opposite, which can save the middle guide vane and reduce the loss of the guide vane , thus  improv ing  the efficiency.

2 .   The form of the direct connection between the motor and the impeller  is adopt ed , which changes the traditional structure of the long shaft of the mine  main fan  or the pulley drive, avoiding damage, and accident of the transmission device, and  also eliminates the energy loss of the transmission device and improves the efficiency of the fan device. Due to its simple structure, in addition to regularly filling fuel to the motor bearings, it generally does not require maintenance and can be operated continuously for a long time.

3. When the motor power of this series of fans is less than 200 KW, it is equipped with the YBF series with an explosion-proof type moto r of  the derived serie s o f YB series ,   and the voltage is   380V, 660V, or 1140V .   W hen the power is above 200 KW, it can be equipped with YBF series of 6000V high voltage explosion-proof energy-saving type motor according to the needs of the mine. The motor is installed in a n  airtight, cover in the main air duct. The airtight, cover has a certain pressure resistance. It can isolate the motor from the gas contained in the fan flow passage and also has a certain effect of heat dissipation. The airtight, cover is equipped with two rows of the streamlined air  pipe , which are  interlinked with the ground atmosphere through the main air duct so that fresh air flows into the airtight cover, and at the same time, the air in the cover can maintain a positive pressure state during the operation of the fan. Due to the use of various technical measures in the design, the motor is always working under the condition that the gas concentration is less than 1%, which meets the safety and explosion-proof requirements.

4. The highest unit of this series of fans can achieve a static pressure efficiency of 86%, the high-efficiency area is wide, and the static pressure efficiency is more than 70% of 70% or more working area .   It  can ensure that the efficiency of the main fan of the mine in the three mining stages is all above 75% , which has  reversed the low operation efficiency of the main fan of large mines in China and sav es  a large amount of  electric energy.

5. A  steady flow ring is installed in the main air duct, the performance curve of the fan has no hump, no surge, and it can run stably under any resistance  condition . The noise is low. Most models of this product have a noise of less than 90 dB (A) without a muffler. If the user has stricter requirements on noise, the product can be equipped with a muffler  when leav ing  the factory.

6. All the blades of this series of fans can be adjusted, which can be divided into five working angles : 45°, 40°, 35°, 30 and 25°. The installation angles of the front and rear stages can be the same, or different, or  can be adjusted to run at any a ngle below 45º . One of the fans can be operated separately, so the adjustable range is extremely wide. In the initial stage of production of the mine, it is ok to run only one class of the fan of it .

7. T his series of fans are stable in operation and low in machine vibration.  A nd the fan s  and diffuser s  are installed on the flatbed truck with wheels, which can run continuously for a long time.


8. T he reverse wind can be reversed. In various working conditions, the reverse wind rate is all above 60%. There is no need for the reverse air duct, and only a  need to build a simple ventilation machine room and an electric control duty room , which   c an save a lot of infrastructure investment.


Specification s   and model s
1 .  FBCDZ (formerly BDK62) series of fans have a total of 24 machine numbers of NO.14-NO.44. To meet the needs of large and medium-sized mines with various kinds of ventilation network parameters, th is  series of fans are respectively equipped with 6, 8, 10, 12-pole three-phase asynchronous motors, and two different types of blade number gradations are adopted: that is, the total number of FBCDZ (formerly BDK62) (A) blades is Z = 32 pieces, and the total number of FBDCZ (formerly BDK62) (B) blades is Z = 24 pieces. Through the above combination, the FBCDZ (formerly BDK62) series of fans have a total of 90 specifications. It solves the problem that the main fan model of the mine is small and the selection is difficult.

2 .  The working range of the static pressure efficiency of this series of fans above 70% is Q = 10.1~462.1 m 3 /S  (that is, Q = 606 ~ 2772 m 3 /min ), and the static pressure is Pst = 57.0 ~ 705.7  mmH 2 O  (that is, Pst = 559~ 6921Pa), which can cover the large and medium-sized mines with various kinds of mine ventilation network parameters, the operation static pressure efficiency of which can be all above 75%.

3. The r epresentation method of the fan model

                                  
4. The e xplosion-proof type of fan:  the   explosion-proof type for coal mine


The fan model and the matching motor power determination
In general, the fan model should be selected according to the most difficult period of ventilation in each stage of mine mining. At the same time, it is also necessary to consider the initial stage of mine, mining  which is u nder the condition of low negative pressure and small air volume, so it should also obtain more than 70% of the operation static pressure efficiency. In this way, it  can give full play to the high-efficiency   and energy-saving role of the FBCDZ (formerly BDK) series of fans .

In  the  mines with a very great  difference in the mine ventilation network parameters in the three stages of mining, in the initial stage of the mining ,   it is ok to run only one class  of the FBCDZ (formerly BDK) series of fans, and the other class  can be used as the backup.

Under normal circumstances, when the FBCDZ (formerly BDK) fan is selected according to the three stages of mining, the operation efficiency of each stage should be above 75%, of which the most difficult period should be above 80%. Suppose the fan with the above-mentioned operating efficiency cannot be found in the sample. In that case,  you can contact our factory to adjust the parameters of the fan to  achieve the conditions mentioned above.

The motor power marked in  S ample T able 2 is the maximum power of this type of fan. In general mine selection, the motor power should be equipped according to the actual ventilation parameters.  The   c alculation method  is :

N= .K(KW)

In which : N- the required motor power, refers to the total power (KW) of the I, II class fans;
P st  - the  total resistance ( Pa ) in the most difficult period of the mine;
Q-the total air volume   ( m 3 /s ) in the most difficult period of the mine;
η st  - check the actual operation condition efficiency of this sample according to the P st  and Q parameters;
K- the power reserve coefficient, generally K = 1.1~1.15;

Calculat e the total power N according to the above, according to the value of N / 2, and refer to the motor power class series, select and equip with two sets of the same power motor, and must make N + N ≤N .  It  is  important to   specifically point out  that : when a certain model of the fan is selected  a nd is calculate d  the N value according to the above formula ,   a fter selecting the motor N =N , it should be compared with the maximum power of the single motor power given in T able 2. If the value of N =N is greater than the maximum power of the single motor given in T able 2, then this model of the fan is not applicable, and a larger size of the fan must be selected.

If the mot or power required  in the early and the later stage s  of the mine are greatly different , it can be compared economically. In the early stage, two motors with smaller power are equipped, and in the later stage, the motors are replaced with high-power ones. In this way, the motors can be operated under the condition of a high er  power factor and high er  efficiency , to   r educe electricity consumption and save electricity costs.
The design service life of the FBCDZ (formerly BDK) series of fan s  is 20 years .


I nstallation
W hen the machine is shipped from the factory, it is the four pieces of the whole machine  that leave the factory, which include   the I-class fan, -the class fan, the diffuser, and the diffusion tower. The pressure test of the airtight, cover has been carried out by the manufacturer by the technical standard requirements   before leaving the factory. Therefore, it is generally not suitable for disassembly. If there is difficulty in moving it and must be disassembled, it can be installed   by the on-site guidance of the manufacturer.
During the installation, the collector must be placed in fresh air ,  so that the air inside the airtight cover does not contain gas.

The ground of the fan installation site should be flat, and according to the gauge in the sample schematic diagram, the auxiliary steel rail should be set, and the 24-38   Kg /M light rail can be selected and used. The steel rail can be pre-embedded on the cement floor surface or fixed on the sleeper.


T est run and operation
Before the fan is installed, the blade should be adjusted first according to the required angle, and all the screws should be tightened. The motor can be refueled at any time during operation. When in operation, the current, the voltage, the motor bearing, and the temperature indicating the instrument of the motor stator should be frequently observed and recorded well. If it  exceed s   the required index  of the technical requirements, it should be immediately stopped  for checking .
During the overhaul of the machine, the sealing gasket of the airtight, cover should be carefully kept and must not be damaged. Once damaged, it should be purchased from the manufacturer.


 
Product Parameters

 


The performance range and main technical parameters   table of the FBCDZ (formerly BDK62) series of explosion-proof axial flow ventilator

 
Series
 
No.
 
Air volume  (m3/s)
Air volume  (m3/s)
(Pa)
F ull pressure (Pa)
M otor model
 
P ower (KW)
 

FBCDZ(B)- 4(n=1450r/min)
12 9.6-29.0 860-3400 YBF250M-4 2 × 55
13 12.2-37.0 1010-4000 YBF280M-4 2 × 90
14 15.2-45.6 1170-4630 YBF315M-4 2 × 132



FBCDZ(A)-6
(n=980r/min)
14 10.1-31.7 918-2888 YBF280M-6 2 × 55
15 12.4-39.0 1054-3315 YBF315S-6 2 × 75
16 15.0-47.3 1199-3772 YBF315L1-6 2 × 110
17 18.0-56.8 1353-4258 YBF315L2-6 2 × 132
18 21.4-67.4 1517-4774 YBF355M2-6 2 × 185
19 25.1-79.3 1690-5319 YBF355L1-6 2 × 220
20 29.3-92.5 1873-5893 YBF355L2-6 2 × 250
21 33.9-107.0 2065-6497 YBF450M1-6 2 × 355






FBCDZ(A)-8
(n=740r/min)
17 13.6-42.9 772-2428 YBF315S-8 2 × 55
18 16.1-50.9 865-2722 YBF315M-8 2 × 75
19 19.0-60.0 964-3033 YBF315L2-8 2 × 110
20 22.1-69.8 1068-3360 YBF355M1-8 2 × 132
21 25.6-80.8 1177-3705 YBF355M2-8 2 × 160
22 29.5-92.9 1292-4066 YBF355L2-8 2 × 200
23 33.7-106.2 1412-4444 YBF450S3-8 2 × 250
24 38.2-120.7 1538-4839 YBF450M2-8 2 × 315
25 43.2-136.4 1669-5250 YBF450M2-8 2 × 315
26 48.6-153.4 1805-5679 YBF560M2-8 2×450
27 54.4-171.8 1946-6124 YBF560M2-8 2 × 450
28 60.7-191.6 2093-6586 YBF630M2-8 2 × 710





FBCDZ(A)-10
(n=590r/min)
20 17.6-55.7 679-2136 YBF315L-10 2 × 75
21 20.4-64.4 748-2355 YBF355M1-10 2 × 90
22 23.5-74.1 821-2585 YBF355M2-10 2 × 110
23 26.8-84.7 898-2825 YBF355L1-10 2 × 132
24 30.5-96.2 978-3076 YBF355L2-10 2 × 160
25 34.5-108.7 1061-3338 YBF355L3-10 2 × 185
26 38.8-122.3 1147-3610 YBF450M2-10 2 × 250
27 43.4-137.0 1237-3893 YBF450M2-10 2 × 250
28 48.4-152.8 1331-4187 JBO710M1-10 2 × 315
29 53.8-169.7 1427-4491 JBO710M2-10 2 × 355
 
Series
 
No. Air   volume  (m3/s) F ull pressure (Pa) M otor model
 
P ower (KW)
 

FBCDZ(A)-10
(n=590r/min)
30 59.5-187.9 1527-4806 JBO800S2-10 2 × 450
32 72.3-228.0 1738-5468 JBO900S1-10 2 × 560
34 86.7-273.4 1962-6173 JBO900S3-10 2 × 800
36 102.9-324.7 2199-6921 JBO900M2-10 2 × 1000






FBCDZ(A)-12
(n=490r/min)
 
24 25.3-79.9 674-2122 JBO355S2-12 2 × 110
25 28.6-90.3 732-2302 JBO355S2-12 2 × 110
26 32.2-101.6 791-2490 JBO400S-12 2 × 132
27 36.1-113.8 853-2685 JBO400M-12 2 × 160
28 40.2-126.9 918-2888 JBO710S1-12 2 × 200
29 44.7-140.9 985-3098 JBO710S1-12 2 × 200
30 49.5-156.0 1054-3315 JBO710M1-12 2 × 250
32 60.0-189.4 1199-3772 JBO800S2-12 2 × 355
34 72.0-227.1 1353-4258 JBO900S1-12 2 × 450
36 85.5-269.6 1517-4774 JBO900M1-12 2 × 560
38 100.5-317.1 1690-5319 JBO900L1-12 2 × 800
40 171.2-370.0 1873-5893 JBO900L2-12 2 × 1000



FBCDZ(B)-6
(n=980r/min)


 
15 14.5-36.6 805-2335 YBF280M-6 2 × 55
16 17.6-44.4 916-2656 YBF315S-6 2 × 75
17 21.1-53.3 1035-2999 YBF315M-6 2 × 90
18 25.0-63.3 1160-3362 YBF315L2-6 2 × 132
19 29.4-74.4 1292-3746 YBF355M1-6 2 × 160
20 34.3-86.8 1432-4150 YBF355L1-6 2 × 220
21 39.7-100.5 1579-4576 YBF450S2-6 2 × 280




FBCDZ(B)-8
(n=740r/min)

 
18 18.9-47.8 661-1917 YBF315S-8 2 × 55
19 22.2-56.2 737-2136 YBF315M-8 2 × 75
20 25.9-65.5 816-2367 YBF315L1-8 2 × 90
21 30.0-75.9 900-2609 YBF355M1-8 2 × 132
22 34.5-87.2 988-2863 YBF355M2-8 2 × 160
23 39.4-99.7 1080-3130 YBF355L1-8 2 × 185
24 44.8-113.2 1176-3408 YBF355L3-8 2 × 220
25 50.6-128.0 1276-3698 YBF450M1-8 2 × 280
26 56.9-144.0 1380-3999 YBF560S2-8 2 × 355
 
Series
 
No.
 
Air volume  (m3/s) F ull pressure (Pa) M otor model
 
P ower (KW)
 
FBCDZ(B)-8
(n=740r/min)
27 63.7-161.0 1488-4313 YBF560S2-8 2 × 355
28 71.1-179.8 1600-4638 YBF560M2-8 2 × 450






FBCDZ(B)-10
(n=590r/min)
 
21 23.9-60.5 572-1659 YBF315L-10 2 × 75
22 27.5-69.5 628-1820 YBF315L-10 2 × 75
23 31.4-79.5 YBF355M1-10 2 × 90
24 35.7-90.3 747-2166 YBF355M2-10 2 × 110
25 40.3-102.1 811-2351 YBF355L2-10 2 × 160
26 45.4-114.8 877-2542 YBF355L3-10 2 × 185
27 50.8-128.6 946-2742 YBF450S3-10 2 × 200
28 56.7-143.4 1017-2949 YBF450M2-10 2 × 250
29 63.0-159.3 1091-3163 YBF450M2-10 2 × 250
30 69.7-176.4 1168-3385 JBO710M1-10 2 × 315
32 84.6-214.0 1329-3851 JBO800S2-10 2 × 450
34 101.5-256.7 1500-4348 JBO900S1-10 2 × 560
36 120.4-304.7 1682-4874 JBO900M1-10 2 × 710







FBCDZ(B)-12
(n=490r/min)


 
25 33.5-84.8 559-1621 JBO355S2-12 2 × 110
26 37.7-95.3 605-1754 JBO355S2-12 2 × 110
27 42.2-106.8 652-1891 JBO400S-12 2 × 132
28 47.1-119.1 702-2034 JBO400M-12 2 × 160
29 52.3-132.3 753-2182 JBO400M-12 2 × 160
30 57.9-146.5 806-2335 JBO710S1-12 2 × 200
32 70.3-177.7 916-2656 JBO710M1-12 2 × 250
34 84.3-213.2 1035-2999 JBO800S1-12 2 × 315
36 100.0-253.1 1160-3362 JBO900S1-12 2 × 450
38 117.6-297.6 1292-3746 JBO900M1-12 2 × 560
40 137.2-347.2 1432-4150 JBO900M2-12 2 × 710
42 158.8-401.9 1579-4576 JBO900L2-12 2 × 1000
44 182.6-462.1 1733-5022 JBO900L3-12 2 × 1250


 
Detailed Photos

Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan

Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan


 
Certifications

 

Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan


 


 
Packaging & Shipping

Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan



1) The equipment is equipped with a number of signs such as a product nameplate, rotation direction sign, wind direction sign, grounding sign, lifting sign, safety warnings, and so on.
2) Product nameplate mainly includes the contents of the equipment: main technical parameters (flow, pressure, motor power, Revolutions Per Minute), product number, manufacturing date, and so on, which is convenient for users to check at any time
3) Small equipment adopts the type of export wood packaging and large equipment, and the steel frame transports large cargo transportation.
4) All equipment is waterproof and rainproof.




 
Company Profile

Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan
 


 
 
 
 
Our Advantages

 

Fbcdz Ventilation Exhaust Primary Draft Tunnel Fan

 

Strict quality standards, precision machining, and other spare parts and design maintain product stability, strictly select product parts suppliers, and perfect after-sales service system to allow customers to enjoy a new experience

Our company has introduced the latest research results of the Chinese Academy of Sciences, C4-II ternary flow wing twisted blades, which have high aerodynamic efficiency.
The surface of the ventilator impeller blade is sprayed with advanced super-resistant (CN) metal material to form a wear-resistant, anti-corrosion protection layer on the surface of the blade. The wear resistance of the blade surface is 10 to 50 times higher than that of the ordinary carbon steel material, thereby greatly prolonging the service life of the blade.

 

Quality assurance measures:

In long-term production management, our company has formed a set of standardized process control measures and control points, which can provide users with high-quality products in all directions. Our company has a good reputation and is an enterprise that users can trust.

Our company has obtained the IS09001 certification from the International Organization for Standardization (see Enterprise Qualification Materials for details). We strictly standardize the operation process and control points of product manufacturing



 
After Sales Service

 

When the equipment  of the buyer  is installed,  our  company is responsible for   on-site installation guidance, personnel training   and   commissioning  of t est - drive The separately purchased fan accessories can be used for telephone connection guidance and debugging

Our company guarantees that the structural safety, aerodynamic performance, running noise, and appearance, quality of the supplied ventilators can be checked and accepted by relevant departments.

The quality assurance period for the supplied ventilator equipment,   except for special provisions, is 18 months from the final acceptance of the ventilator.


 
FAQ

 

Q. What information should I provide when inquiring?

A: Fan name/model, KW, Air pressure, Flow rate Air Volume, and temperature

Q. What is your warranty?
A. Our warranty is 18 months after receiving the fans. During the warranty period, replace the damaged parts free of charge. Out warranty period, to provide timely, high-quality technical services and price concessions spare parts to ensure.
continuous safe and high-quality equipment operation.

Q. How does your factory control product quality?
A. We have a quality inspection department. All fans are running more than 3 hours before delivery to test the quality. If there is a quality problem, we will produce a new one.

Q. What are your terms of payment?
A. TT 40% AS THE ADVANCE PAYMENT AND TT 60% AFTER INSPECTION BEFORE SHIPPING.
B. 100% IRREVOCABLE L/C AT STGHT.

Q. What products do you produce?
A. Centrifugal fan, tunnel fan, axial fan, jet fan, mining fan, exhaust fan,anti-corrosion blower, high-pressure blower, explosion proof fan, fan accessories, etc, welcome to contact us to learn more details.

Q. Where is your factory? Can I visit your factory?
A. Zibo Hengding Fan Co., Ltd. Is located in Industrial Park, Beijiao Town, Zhoucun District, Zibo City, Shandong Province, China.

Q. How long will it take to ship after the order?
A. 10-15 Days if you need it urgently, we can discuss it for shorting time.

Q. Is the product customizable?
A. Various types can be customizable.



 

PNEUTEC.IT, 2023