>pure sine wave output inverter
> according to the load requirements, the battery charging current can be set through LCD
> the priority input mode of mains / solar energy can be set through the LCD
> compatible with mains power and generator input
> automatic restart function when mains power is restored
> overload, high temperature and short circuit protection
> intelligent battery charging design makes the battery more fully utilized
> cold start function
| Model | OLU3024VMII | OLU3524VMII | OLU3048VMII | OLU3548VMII | OLU5048VMII | |
| Rated Power | 3KW | 3.5KW | 3KW | 3.5KW | 5KW | |
| AC Output | AC Voltage | Single phase 220VAC/230VAC settable,±5% | ||||
| Efficiency (at peak) | 93% | |||||
| Conversion time |
10ms (personal computer);
20ms (Household electric appliances) |
|||||
| Wave form | Pure sine wave | |||||
| Battery | Battery voltage | 24VDC | 48VDC | |||
| Floating charge voltage | 27VDC | 54VDC | ||||
| Overcharge protection | 33VDC | 63VDC | ||||
| Solar Input | Max Input Power | 3.5KW | 4KW | 3.5KW | 4KW | 5KW |
| MPPT range@working voltage | 120~450VDC | |||||
| Max PV Array Open Circuit Voltage | 500VDC | |||||
| Max PV Charging Current | 18A / 80A | |||||
| AC Input | Voltage | 230VAC | ||||
| Voltage range | 90-280VAC (home appliance)/170-280VAC (pc) | |||||
| Frequency range | 50HZ / 60HZ (self-adaptive) | |||||
| Max AC Charging Current | 80A | 100A | 60A | 60A | 60A | |
| Physics |
Dimension
D*W*H (mm) |
507*301*110 | ||||
| Weight (kg) | 9 | 10 | ||||
| Communication Mode | RS485/ CAN/ Dry Contact | |||||
| Operating Environment | Humidity | 5%~95% Relative humidity (non-condensing) | ||||
| Working Temperature | -20 ºC ~+50 ºC | |||||
| Storage Temperature | -30 ºC ~+70 ºC | |||||
| Protection Level | IP20 | |||||
Nanjing Oulu Electric Co., Ltd. (STOCK NUMBER:871415) was established in 1996 and began to manufacture small and medium sized wind turbine generator in early 2007.