Solar Hybrid Inverter Single Phase Solar PV Energy System Pure Sine Wave
| Model | OLU5532 | OLU1033 | OLU1533 |
| PHASE | 1-phase in/1 phase out | 3-phase in/3-phase out | 3-phase in/3-phase out |
| Max.PV INPUT POWER | 6500W | 14850W | 22500W |
| Rated Output Power | 5500W | 10000W | 15000W |
| Maximum Charging Power | 2880 W | 9600 W | 15000 W |
| GRID TIE OPERATION | |||
| PV INPUT (DC) | |||
| Nominal DC Voltage/Max. DC Voltage | 360 VDC/500 VDC | 720 VDC/900 VDC | 720 VDC/900 VDC |
| Start-up Voltage/Initial Feeding Voltage | 116 VDC/150 VDC | 320 VDC/350 VDC | 320 VDC/350 VDC |
| MPP Voltage Range | 120 VDC~450 VDC | 400 VDC~800 VDC | 400 VDC~800 VDC |
| Number of MPP Trackers | 2/2x13A | 2/2x18.6A | 2/A: 37.65A; B:18.6A |
| Maximum Input Current | |||
| GRID OUTPUT (AC) | |||
| Nominal Output Voltage | 220/230/240 VAC | 230 VAC (P-N) | 230 VAC (P-N) |
| 400 VAC (P-P) | 400 VAC (P-P) | ||
| Output Voltage Range | 184-265VAC | 184 -265 VAC* per phase | 184 - 265 VAC* per phase |
| Nominal Output Current | 23.9A | 14.5A per phase | 21.7A per phase |
| Power Factor | > 0.99 | ||
| EFFICIENCY | |||
| Maximum Conversion Efficiency (DC/AC) | 96% | ||
| European E | 95% | ||
| OFF GRID OPERATION | |||
| AC INPUT | |||
| AC start-up Voltage/ | 120- 140VAC/180VAC | 120- 140VAC per phase | 120- 140VAC per phase |
| Auto Restart Voltage | 180 VAC per phase | 180 VAC per phase | |
| Acceptable Input Voltage Range | 170-280VAC | 170-280VAC per phase | 170-280 VAC per phase |
| Max. AC Input Current | 40A | 40A | 40A |
| PV INPUT (DC) | |||
| Max. DC Voltage | 500 VDC | 900 VDC | 900 VDC |
| MPP Voltage Range | 120 VDC~450 VDC | 400 VDC~800 VDC | 350 VDC~850 VDC |
| Number of MPP Trackers/Max. Input Current | 2/2x13A | 2/2x18.6A | 2/A: 37.65A; B:18.6A |
| BATTERY Mode Output (AC) | |||
| Nominal Output Voltage | 220/230/240VAC | 220/230/240 VAC | 230VAC (P-N) / 400VAC (P-P) |
| Output Waveform | Pure Sine Wave | ||
| Efficiency (DC to AC) | 93% | 91% | 91% |
| HYBRID OPER | TION | ||
| PV INPUT (DC) | |||
| Nominal DC Voltage/Max. DC Voltage | 360 VDC/500 VDC | 720 VDC/ 900 VDC | 720 VDC/ 900 VDC |
| Start-up Voltage/Initial Feeding Voltage | 116 VDC/150 VDC | 320 VDC/ 350 VDC | 320 VDC/ 350 VDC |
| MPP Voltage Range | 120 VDC~450 VDC | 400 VDC~800 VDC | 350 VDC~850 VDC |
| No. of MPP Trackers/Max. Input Current | 2/2x13A | 2/2x18.6A | 2/A: 37.65A; B:18.6A |
| GRID OUTOUT (AC) | |||
| Nominal Output Voltage | 202/208/2023/230/240 VAC | 230 VAC (P-N)/ | 230 VAC (P-N)/ |
| 400 VAC (P-P) | 400 VAC (P-P) | ||
| Output Voltage Range | 184-264.5 VAC* | 184-264.5 VAC* per phase | 184-264.5 VAC* per phase |
| Nominal Output Current | 23.9A | 14.5A per phase | 21.7A per phase |
| AC INPUT | |||
| AC Start-up Voltage/Auto Restart Voltage | 120- 140VAC/180VAC | 120- 140VAC per phase / 180VAC per phase | 120- 140VAC per phase/ 180VAC per phase |
| Acceptable Input Voltage Range | 170-280 VAC | 170-280 VAC | 170-280 VAC per phase |
| Max. AC Input Current | 30A | 30A | 40A |
| BATTERY MODE OUTPUT (AC) | |||
| Nominal Output Voltage | 202/208/220/230/240 VAC | 230 VAC (P-N)/ | 230 VAC (P-N)/ |
| 400 VAC(P-P) | 400 VAC(P-P) | ||
| Efficiency (DC to AC) | 93% | 91% | 91% |
| BATTERY& CHARGER | |||
| Battery DC Voltage | 48V | ||
| Max. Charging Current | Default 60A | Default 60A,10A-200A Adjustable | Default 60A, 5A-300A Adjustable |
| GENERAL | |||
| PHYSICAL | |||
| Dimension, D x W x H (mm) | 110*450*445 | 167.5*500*622 | 219*650*820 |
| Net weight (kgs) | 16 | 45 | 62 |
| INTERFACE | |||
| Communication Port | RS-232/USB and CAN Interface | RS-232, USB and Dry contact | |
| ENVIRONMENT | |||
| Humidity | 0 ~90%RH | ||
| Operating Temperature | 0 to 40 ° C | - 1 0 to 55 ° C | |
| Altitude | 0- 1000 m** | ||
Nanjing Oulu Electric Corp., Ltd. (STOCK NUMBER:871415) was established in 1996 and began to manufacture small and medium sized wind turbine generator in early 2007.