Y9-35 ventola della caldaia aspirazione singola ventola ad alta temperatura

Model No.
Y9-35NO. 8D~21.5F
tempo di consegna
15 giorni
velocità di rotazione
1450-580 giri/min
flusso volumetrico
3710~311000m3/h.
Pacchetto di Trasporto
Shipping Case Packing
Specifiche
According to demand
Marchio
Huayu
Origine
Shandong China
Codice SA
8414593000
Capacità di Produzione
10000/Year
Prezzo di riferimento
$ 360.00 - 2,700.00

Descrizione del Prodotto

Y9-35 Boiler fan Single suction high temperature fan
Product Description

The purpose of the fan

Y9-35 type single-suction boiler centrifugal fan and Y9-35 type single-suction and Y9-35 double-suction boiler induced draft fans are suitable for ventilation and induction systems of 2~240t/h steam boilers. The basic model of the ventilator is "9-35", and the basic model of the induced draft fan is "Y9-35".

 
Model No G Y9-35 6D-21.5F
Product name Centrifugal Fan
Application Industries Widely used in large and medium-sized factories, power plants, air treatment equipment, hot air circulation equipment, and factory/building ventilation air/gas transport cooling and generally, used for ventilation, process gas transport, etc. 
Rotating Speed 1450-580 rpm
Power 4~320KW
Material Q235,Stainless steel , other
Total Pressure 1912~2853Pa
Airflow 3710~311000M3/H
 Voltage 380V/400V/415V/440V/450V/660V/1140V
Frequency 50Hz/60Hz
Temperature Resistance 200~600 Degrees
Color Blue/White/Grey/Yellow/Customized
Package Wooden Box/Steel frame
Specification Can provide according to customers requirements sizes
Impeller Type Backward/Forward/Radial Blade
Efficiency(%) Over 90%
Exported to All Countries
Place of Origin Shandong China
Brand Name Huayu
Warranty 18 Months
After-Sales Service Field Installation, Commissioning, and Training
 
Detailed Photos

Y9-35 Boiler Fan Single Suction High Temperature Fan Y9-35 Boiler Fan Single Suction High Temperature Fan

 Type of fans

  1) Supplementary models for single-suction and induced draft fans are "11" or "12", supplementary models for double-induced fans are "03", where the first digit 1 and 0 represent single-suction and double-suction, and the second digit The numbers are design serial numbers. Refer to the performance table for the performance parameters of the ventilation and induced draft fans.

2) The transmission mode is connected to the motor coupling and transmission, the single suction fan is D type, and the double suction fan is F type.

3) Looking at the rotation direction of the impeller from the direction of the motor, the clockwise one is called a forward fan, and the counterclockwise one is called a reverse fan.

The structure of the fan

   1) The impeller is welded by forward-curved blades, a conical front disk, and a flat rear disk (or middle disk), and riveted on the shaft disk. The blades of the induced draft fan are thicker due to greater wear. And the root of the blade on the back plate (or middle plate) is welded with a wear-resistant layer to prolong the service time.

   2) The main shaft of the transmission part is made of high-quality steel. The single-suction fan, induced draft fan, and double-suction induced draft fan all use rolling bearings. The bearings are equipped with thermometers and oil level indicators, and the induced draft fan has a cooling water device.

   3) The casing is a volute body welded with steel plates. There is a thick liner on the volute plate of the induced draft fan for replacement after wear and tear.

   4) Single-suction and induced draft fans are equipped with eight petal-type flow regulators at the inlet, and double-suction induced draft fans are equipped with four simple flow regulators on the air intake boxes on both sides to adjust the user flow.


Applications of Induced draft fan Industrial air blower centrifugal fans
 
Ventilating
Forced ventilating, Building ventilating, Mine ventilating, Tunnel ventilating, Materials ventilating and drying.
 Cooling and heat dissipation
Forced cooling and heat dissipation, Industrial equipments cooling and heat dissipation.
 Air purification and industrial waste gas treatment, Air filtration system, Flue gas desulfurization, Flue gas denitrification.
Boiler's air supply and exhaust (Coal-fired boiler, Biomass boiler, Garbage incinerator, CFB boiler, Stoker feed boiler.).
Industrial boiler blowing air, Industrial boiler inducing air, Industrial boiler primary air, Industrial boiler secondary air.
 Industrial boiler waste gas desulfurization, Industrial boiler flue gas denitrification.


Y9-35 Boiler Fan Single Suction High Temperature Fan

The following points should be paid attention to durning the process of installation:
 
(1) Smear some graese or machine oil on some junction surfaces in order to prevent rusting, and reduce the
 
difficulties when moved.
 
(2) When fixing the scew bolts on the junction surfaces,if there are Positioning pins,fix the Positioning pins first
 
then the screw blots.
 
(3) Check the inside of the chasssis and other cases to make sure that no tools and other substances are left in it .  
Product Parameters

Techinical Parameters(Other parameters welcome email consultation): 

     
Model
number
Type
No
Pressure
Pa
Flow Rate
m3/h
Motor


G9-35


6D
1912 3710 4-4
2000-2098 4640-6500 4-7.5
2108-1990 7430-10220 4-11
833-921 2460-5530 6-3
912-973 6140-6750 6-4

Model
number
Type
No
Pressure
Pa
Flow Rate
m3/h
Motor










G9-35


8D
1490-1549 5810-7270 6-7.5
1598-1834 8720-13080 6-11
1608-1540 14640-16000 6-15
863-932 4430-6650 8-4
941-951 7760-9980 8-5.5
932-892 11090-12200 8-7.5




10D
2324 11350 6-15
2412-2510 14200-17050 6-22
2549-2569 19900-22750 6-30
2569-2520 25600-28400 6-37
2412 31250 6-45
1353-1412 8650-10800 8-7.5
1451-1481 13000-15150 8-11
1461-1402 21600-23800 8-18.5
1491 17300-19450 8-15



12D
3353 19620 6-37
3305 24520 6-45
3521 29420 6-55
3677-3697 34330-39230 6-75
3697-3638 44140-49040 6-90
3481 63940 6-110
1893 14920 8-15
 
Model
number
Type
No
Pressure
Pa
Flow Rate
m3/h
Motor











G9-35

12D
2023 18650 8-22
2088-2128 22380-26110 8-30
2137 29840-33570 8-37
2098-2010 37300-41030 8-45





13.5D
2451 21240 8-30
2559-2648 26550-31860 8-37
2687 37170 8-45
2707 42480-47790 8-55
2658-2550 53100-58410 8-75
4236-4433 27920-34900 6-75
4560 41880 6-110
4658-4678 48860-55840 6-132
4678 62820 6-160
4599-4413 69800-76780 6-185
15.5D 3236 32160 8-55
3383-3481 40200-48240 8-90
3550-3569 56280-64320 8-110
3569 72360 8-132
3501-3364 80400-88440 8-160
2039-2196 25600-38400 10-45
2245-2255 44800-51200 10-55
2255 57600 10-75
2216-2118 64000-70400 10-90
 
Model
number
Type
No
Pressure
Pa
Flow Rate
m3/h
Motor










G9-35








18D
 
4364 50400 8-132
4560 63000 8-160
4707 75600 8-185
4785 88200 8-220
4815 10800 8-250
4815 113400 260
4726 126000 310
4530 138600 370
2755 40080 10-75
2883-2971 50100-60120 10-90
3020 70140 10-110
2951 80160 10-132
2951-2991 90180-100200 10-160
2863 110220 10-185



20D
5393 69200 220
5639 86500 250
5805 103800 284
5913 121100 380
5952-5925 138400-15570 440
5844 173000 500
5599 190300 625
3403 54960 10-90
 
Model
number
Type
No
Pressure
Pa
Flow Rate
m3/h
Motor


G9-35


20D
3756 68700 10-132
3667 82440 10-160
3736 96180 10-185
3756 109920 200
3756 123660 230
3687-3540 13740-151140 280








Y9-35


8D
921-961 5810-1270 6-4
1000-1020 8720-13080 6-7.5
1000-961 14540-16000 6-11
539-578 4430-11090 8-4
558 12200 8-5.5





10D
1451 11350 6-11
1510-1559 14200-17050 6-15
1588 19900 6-18.5
1598-1608 22750-25600 6-22
1569-1500 28400-31250 6-30
843-872 8650-10800 8-5.5
902-922 13000-15150 8-7.5
922 17350-19450 8-11
912-872 21600-23800 8-15
12D 2079-2177 19620-24520 6-30
2245 29420 6-37
 
Model
number
Type
No
Pressure
Pa
Flow Rate
m3/h
Motor












Y9-35




12D
 
2285 34330 6-45
2294 39230-44140 6-55
2255-2167 49040-53940 6-75
1206-1255 14920-18650 8-15
1294 22380 8-18.5
1323 26110-29840 8-22
1323-1304 33570-37300 8-30
1245 41030 8-37





13.5D
2638-2755 27920-34900 6-55
2834-2893 41880-48860 6-75
2912 55840 6-90
2912-2736 62820-76780 6-132
1520 21240 8-22
1588-1647 26550-31860 8-30
1676 37170 8-37
1686 42480-47790 8-45
1657-1578 53100-58410 8-55


15.5D
2010 32160 6-45
2098 40200 8-55
2167-2206 48240-56280 8-75
2216 64320-72360 8-90
2177-2088 80400-88440 8-110
 
Model
number
Type
No
Pressure
Pa
Flow Rate
m3/h
Motor










Y9-35
15.5D 1323-1372 32000-64000 10-45
1314 70400 10-55






18D
 
2706 50400 8-75
2824 63000 8-110
2922 75600 8-132
2971 88200 8-160
2991 100800-113400 8-185
2942 126000 8-220
2814 138600 8-250
1716 40800 10-45
1784 50100 10-55
1843 60120 10-75
1873-1892 70140-90180 10-90
1853-1775 100200-110220 10-110




20D
3344 69200 8-132
3501 86500 8-185
3608 103800 8-220
3677 121100 8-250
3697 138400 315
3697-3628 155700-173000 380
3481 190300 400
2118-2206 54960-68700 10-90

Model
number
Type
No
Pressure
Pa
Flow Rate
m3/h
Motor











Y9-35
 
20D 2275 82440 10-110
2324 96180 10-132
2334 109920-123660 10-160
2294 137400 10-185
2196 151140 220






13.5F


 
2844 55800 6-90
2981 69800 6-110
3040 83800 6-160
3079-3020 97600-111600 6-185
2981 125500 6-200
2902-2804 139600-153500 6-250
1637 42400 8-45
1716 53000 8-55
1755 63600-74200 8-75
1745 84800 8-90
1716-1618 65500-116500 8-110
1039-1088 33700-75800 10-45
1059-1029 84400-92600 10-55

15.5F
 
2157-2255 64300-80500 8-110
2304 36500 8-132
2353-2304 112500-192000 8-160
2255 145000 8-185
 
Model
number
Type
No
Pressure
Pa
Flow Rate
m3/h
Motor










Y9-35



15.5F
2206 161000 210
2137 171000 245
1372 51200 10-45
1431 64000 10-55
1471 76800 10-75
1480-1431 89500-115000 10-90
1402-1353 128000-140500 10-110



18F
2922-3138 100800-151200 260
3177-3118 176400-201600 310
3069 226800 370
2991-2893 252000-277200 440
1843-1931 80000-180000 200
1892-1824 200000-220000 230
1265-1245 96250-182200 12-132
  Application
 industrial systems such as Coal-fired power, Metallurgy, Papermaking, Cement and Glass production, Chemical industry, Material handling, Sewage treatment, Waste incineration, Subway ventilation, environment protection, mine, metallurgy, petro-chemical, tunnel,Industrial boiler and Dust removal systems etc. , and wind tunnel

Y9-35 Boiler Fan Single Suction High Temperature Fan Y9-35 Boiler Fan Single Suction High Temperature Fan Y9-35 Boiler Fan Single Suction High Temperature Fan Y9-35 Boiler Fan Single Suction High Temperature Fan
FAQ

FAQ
1.Q: What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.

2. Q:What is your delivery time?
 A:15-35workdays, depending on the model of the fan.

3.Q:What's your   MOQ?
A:The MOQ is 1set,but larger quantity, lower price.

4.Q: What's your   warranty?
A: 12 months after arrival of the goods on site.

5.Q:How do you control the product's   quality?
A:All the products have quality testing and dynamic balance before delivery.

 



 

 