Loi-a ASTM D2863 Automatic Lol Limiting Oxygen Index Chamber for Plastics

Model NO.
LOI-A
Weight
10kg
Gas Supplies
Oxygen, Nitrogen and Propane
Oxygen Range
0 - 100%
Trade Term
EXW, Fob, DDU, CNF, CIF, etc.
Payment Term
30% T/T as Deposit, The Balance Before Delivery
Delivery Lead Time
10 Days
Power Supply
220V, 50Hz
Reference Standards
ASTM D 2863, ISO 4589-2, Nes 714
Test Method
Automatic Paramagnetic Type
Description
ASTM D2863 Automatic Limiting Oxygen Index Chamber
Oxygen Sensor
Paramagnetic Type
Application Field
Building Material, Cable, Rail, Plastic, etc.
Transport Package
Limited Oxygen Index Tester Pack in Veneer Case
Specification
45cm * 40cm * 60cm
Trademark
Delta
Origin
China Mainland
HS Code
9031809090
Production Capacity
1000 Sets Limiting Oxygen Index Chamber / Month
Package Size
56.00cm * 50.00cm * 76.00cm
Package Gross Weight
30.000kg
Reference Price
$ 1,800.00 - 7,200.00

Product Description

LOI-A ASTM D2863 Automatic LOl Limiting Oxygen Index Chamber
Product Description
  1. LOI-A ASTM D2863 Automatic LOl Limiting Oxygen Index Chamber is designed to test combustibility by oxygen concentration, letting user know minimum oxygen concentration as necessary for combustion.

    The working principle is: Place the specimen into the testing chimney, filling with oxygen and nitrogen into the chimney, burn the specimen, then measure the min concentration of oxygen to support continuous combustion.
    Loi-a ASTM D2863 Automatic Lol Limiting Oxygen Index Chamber for Plastics
Product Parameters
  
No. Item Name LOI-A  ASTM D2863 Automatic LOl Limiting Oxygen Index Chamber
1 Size 450 mm (W) x 400 mm (D) x 600 mm (H)
2 Weight 10kg
3 Power Supply 115 Volts AC 60Hz / 230 Volts AC 50Hz
4 Gas Supplies  Oxygen, Nitrogen and Propane
5 Oxygen Sensor Range:0 to 100% Oxygen
6 Oxygen concentration sensor England Servomex Paramagnetic type oxygen sensor, accuracy: +/-0.1%
Reference Standards
  1. ASTM: ASTM D2863: Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index).
  2. ISO: ISO 4589-2: Determining the minimum volume fraction of oxygen, in admixture with nitrogen, that will support combustion of small vertical test specimens under specified test conditions. The results are defined as oxygen index (OI) values.
  3. NES: NES 714.
Features
  1. Adopts England original Servomex Paramagnetic type oxygen sensor, which accuracy can be up to +/-0.1%;
  2. The sensor is better than traditional electrochemical sensor, because it don't need to change oxygen battery, so, it has long lift time more accurate and faster response time.
  3. Equipped with 2pcs Mass Flow Controller(MFC) to control N2 and O2 mixing ratio;
  4. Equipped with high temperature quartz glass tank;
  5. Equipped with supported and unsupported sample clamps;
  6. Equipped with portable ignition device, gas tank connector, accurate pin valve to adjust the flame;
  7. Digital setting N2 and O2 concentration;
  8. Computer+LABVIEW software to control N2 and O2 mixing ratio, read O2 concentration in mixing chamber, and store&print out test results;
  9. Reserve a calibration port to calibrate the sensor;
  10. Stainless steel air channel design, equipped with one way fire-resistance valve, magnetic valve, fine filter, so, it is stable and safe;
  11. Patented design gas mixing chamber, which ensure the gases can mix the gases in short time, data is more accurate;
  12. Resolution: 0.1%
  13. Accuracy: +/-0.2%
  14. Response time: <300ms
  15. Oxygen stability time: <30s
Loi-a ASTM D2863 Automatic Lol Limiting Oxygen Index Chamber for Plastics
LOI-A ASTM D2863 Automatic LOl Limiting Oxygen Index Chamber can connect with computer.
 
  1.  
Software: In Chinese and English languages.
Loi-a ASTM D2863 Automatic Lol Limiting Oxygen Index Chamber for Plastics


 
Our Advantages

1. High Quality Product: Most equipment have been on sale for more than 10 years, they are stable, reliable, with high quality and good reputation. All the products have been tested, run well and adjusted to good condition before delivery.

2. Good Faith Cooperation: Honesty is our foundation, we don't brag about the company and products, seek truth from facts, and don't make random promises.

3. Innovative Technology: Based on full experience in designing and manufacturing these equipment, and with users' feedback, we continuously improving our equipment and developing new products.

4. Awesome Service: Provide professional advice and reasonable offers within 2 hours at working time, and within 12 hours at non-working time. One year warranty for all the products, life time technical consulting, life time provision of spare parts, free software upgrades.

 
 

Loi-a ASTM D2863 Automatic Lol Limiting Oxygen Index Chamber for Plastics

After Sales Service
1.    Warranty period for all products is One year;

2.    Within warranty period, all quality problems of the instrument shall be repaired by our company free of charge;

3.    Beyond warranty period, our company shall be responsible for life-time maintenance, only the cost of the accessories will be charged;

4.    User manual will be sent with the tester, some testers have demo for review.

5.    If users have question on operation, we supply on-line video training. Users can also come to our factory to get free training.

 

 

PNEUTEC.IT, 2023