Rated Capacity (kVA) | Voltage Combined | Vector- group | No-load Loss (w) |
75
ºC
load Loss (w) |
No-load
current (%) |
Short- circuit
impedance (%) |
||
HV(KV) | Tapping Ranges | LV(KV) | ||||||
30 |
6
6.3 10 10.5 11 |
±5%
±2×2.5% |
0.4 |
Dyn11
Yyn0 |
100 | 630/600 | 0.8 | 4.0 |
50 | 130 | 910/870 | 0.75 | |||||
63 | 150 | 1090/1040 | 0.75 | |||||
80 | 180 | 1310/1250 | 0.70 | |||||
100 | 200 | 1580/1500 | 0.65 | |||||
125 | 240 | 1890/1800 | 0.65 | |||||
160 | 280 | 2310/2200 | 0.6 | |||||
200 | 340 | 2730/2600 | 0.5 | |||||
250 | 400 | 3200/3050 | 0.5 | |||||
315 | 480 | 3830/3650 | 0.45 | |||||
400 | 570 | 4520/4300 | 0.45 | |||||
500 | 680 | 5410/5150 | 0.40 | |||||
630 | 810 | 6200 | 0.40 | 4.5 | ||||
800 | 980 | 7500 | 0.35 | |||||
1000 | 1150 | 10300 | 0.35 | |||||
1250 | 1360 | 12000 | 0.30 | |||||
1600 | 1640 | 14500 | 0.30 |
Rated Capacity (kVA) | Voltage Combined | Vector- group | No-load Loss (w) |
75
ºC
load Loss (w) |
No-load
current (%) |
Short- circuit
impedance (%) |
||
HV(KV) | Tapping Ranges | LV(KV) | ||||||
30 | 20 |
±5%
±2×2.5% |
0.4 | Dyn11 | 90 | 660 | 2.1 | 5.5 |
50 | 130 | 960 | 2.0 | |||||
63 | 150 | 1145 | 1.9 | |||||
80 | 180 | 1370 | 1.8 | |||||
100 | 200 | 1650 | 1.6 | |||||
125 | 240 | 1980 | 1.5 | |||||
160 | 290 | 2420 | 1.4 | |||||
200 | 330 | 2860 | 1.3 | |||||
250 | 400 | 3350 | 1.2 | |||||
315 | 480 | 4010 | 1.1 | |||||
400 | 570 | 4730 | 1.0 | |||||
500 | 680 | 5660 | 1.0 | |||||
630 | 810 | 6820 | 0.9 | 6.0 | ||||
800 | 980 | 8250 | 0.8 | |||||
1000 | 1150 | 11330 | 0.7 | |||||
1250 | 1350 | 13200 | 0.7 | |||||
1600 | 1630 | 15950 | 0.6 | |||||
2000 | 1950 | 19140 | 0.6 | |||||
2500 | 2340 | 22220 | 0.5 |
Rated Capacity (kVA) | Voltage Combined | Vector- group | No-load Loss (w) |
75
ºC
load Loss (w) |
No-load
current (%) |
Short- circuit
impedance (%) |
||
HV(KV) | Tapping Ranges | LV(KV) | ||||||
630 | 35 | ±5% |
3.15
6.3 10.5 |
Yd11 | 830 | 7870 | 1.10 | 6.5 |
800 | 980 | 9410 | 1.00 | |||||
1000 | 1150 | 11540 | 1.00 | |||||
1250 | 1410 | 13940 | 0.90 | |||||
1600 | 1700 | 16670 | 0.80 | |||||
2000 | 2180 | 18380 | 0.70 | |||||
2500 | 2560 | 19670 | 0.60 | |||||
3150 | 35-38.5 | ±5% |
3.15
6.3 10.5 |
3040 | 23090 | 0.56 | 7.0 | |
4000 | 3620 | 27360 | 0.56 | |||||
5000 | 4320 | 31380 | 0.48 | |||||
6300 | 5250 | 35060 | 0.48 | 7.5 | ||||
8000 | 35-38.5 | ±2×2.5% |
3.15
3.3 6.3 6.6 10.5 11 |
Ynd11 | 7200 | 38480 | 0.42 | |
10000 | 8700 | 45320 | 0.42 | |||||
12500 | 10080 | 53870 | 0.40 | 8.0 | ||||
16000 | 12160 | 65840 | 0.40 | |||||
20000 | 14400 | 79520 | 0.40 | |||||
25000 | 17020 | 94050 | 0.32 | |||||
31500 | 20230 | 112860 | 0.32 |
Rated Capacity (kVA) | Voltage Combined | Vector- group | No-load Loss (w) |
75
ºC
load Loss (w) |
No-load
current (%) |
Short- circuit
impedance (%) |
||
HV(KV) | Tapping Ranges | LV(KV) | ||||||
30 |
6
6.3 10 10.5 11 |
±5%
±2×2.5% |
0.4 |
Dyn11
Yyn0 |
80 | 630/600 | 0.80 | 4.0 |
50 | 100 | 910/870 | 0.75 | |||||
63 | 110 | 1090/1040 | 0.75 | |||||
80 | 130 | 1310/1250 | 0.70 | |||||
100 | 150 | 1580/1500 | 0.65 | |||||
125 | 170 | 1890/1800 | 0.65 | |||||
160 | 200 | 2310/2200 | 0.60 | |||||
200 | 240 | 2730/2600 | 0.50 | |||||
250 | 290 | 3200/3050 | 0.50 | |||||
315 | 340 | 3830/3650 | 0.45 | |||||
400 | 410 | 4520/4300 | 0.45 | |||||
500 | 480 | 5410/5150 | 0.40 | |||||
630 | 570 | 6200 | 0.40 | 4.5 | ||||
800 | 700 | 7500 | 0.35 | |||||
1000 | 830 | 10300 | 0.35 | |||||
1250 | 970 | 12000 | 0.30 | |||||
1600 | 1170 | 14500 | 0.30 | |||||
2000 | 1550 | 18300 | 0.25 | |||||
2500 | 1830 | 21200 | 0.25 |
Q: What certificates and standard does your company have? |
A: Our factory has ISO9001:2008, ISO14001:2004, OHSAS18001:2007 certificates.
We can send products to appointed laboratories for testing if necessary. |
Q: How long is your delivery time? |
A:For 10KV distribution transformer, the production cycle of our factory is 20~25 days. |
Q: What is your service? |
A: we have quick response in before sales period help you got order, and excellent service in production time let you know each step we made. |
Q: What is the guarantee? |
A: Generall 1-2 years,when the guarantee period ends up, we are responsible for life-long maintenance and would charge some fees concerning costs. |
Q: What is the standard of package? |
A: Export standard package or special package according to customer requirement |
Q:What is your payment term? |
A:All terms of payment is acceptable. |