Product Overview
| The condition of EDI influent water quality | |
| Inlet water | RO permeate water |
| Best conductivity | 2~10μS/cm |
| max. conductivity | ≤30μS/cm |
| Tempture | 5 ºC~38ºC |
| PH | 5~9 |
| Water hardness | < 0.5 mg/LasCaCO3 |
| Silicon | <0.5mg/L |
| TOC | <0.5 mg/L |
| Remaining Cl | <0.05mg/L |
| Fe,Mn,H2S | <0.01 mg/L |
| Influent Water pressure | 0.15~0.45MPa |
| particle | ≤5μm |
| Total CO2 ) | <3mg/L |
| Model | Flow | Electrical resistivity |
Power
(kw) |
Rated Voltage
(V) |
Recovery | Inlet | Pure Water |
| XSTEDI05 | 5 | 15-18.2 | 1 | 220V/380V | 85-95% | DN20 | DN20 |
| XSTEDI0 | 1 | 15-18.2 | 1 | 220V/380V | 90-95% | DN25 | DN25 |
| XSTED20 | 2 | 15-18.2 | 1 | 380V | 90-95% | DN25 | DN25 |
| XSTEDI30 | 3 | 15-18.2 | 1 | 380V | 90-95% | DN25 | DN25 |
| XSTEDI40 | 4 | 15-18.2 | 1 | 380V | 90-95% | DN32 | DN32 |
| XSTEDI50 | 5 | 15-18.2 | 1 | 380V | 90-95% | DN32 | DN32 |
| XSTEDI80 | 8 | 15-18.2 | 2 | 380V | 90-95% | DN40 | DN40 |
| XSTEDI100 | 10 | 15-18.2 | 2.5 | 380V | 90-95% | DN50 | DN50 |