SPECIFICATION | ||||||
OUTPUT | ||||||
Model | LR S- 7 5 - 5 | LR S- 7 5 -12 | LR S- 7 5 -15 | LR S- 7 5-24 | LR S- 7 5-36 | LR S- 7 5 -48 |
D C Voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated Current | 14 A | 6 A | 5 A | 3.2 A | 2.1 A | 1.6 A |
Current Range | 0~ 14 A | 0~ 6 A | 0~ 5 A | 0~ 3.2 A | 0~ 2.1 A | 0~ 1.6 A |
Rated Power | 70 W | 72 W | 75 W | 76.8 W | 75.6 W | 76.8 W |
Ripple & Noise | 10 0mVp-p | 1 2 0mVp-p | 1 2 0mVp-p | 150mVp-p | 2 0 0mVp-p | 2 0 0mVp-p |
Voltage Adj. Range | 4.5 ~ 5.5 V | 1 0 .2 ~ 13. 8 V | 13.5~18V | 2 1.6 ~2 8.8 V | 32 .4 ~ 39.6 V | 4 3.2 ~5 2.8 V |
Voltage Tolerance | ± 2 .0% | ±1. 0 % | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ± 1 . 0 % | ± 0.5 % | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise Time | 5 00ms, 3 0ms/230VAC 5 00ms, 3 0ms/115VAC at full load | |||||
Hold Up Time | 60 ms/230VAC 1 2 ms/115VAC at full load | |||||
INPUT | ||||||
Voltage Range | 85 ~ 264VAC 120 ~ 37 3 VDC | |||||
Frequency Range | 47 ~ 63Hz | |||||
Efficiency | 86.5 % | 8 9 % | 8 9 % | 90 % | 91.5 % | 91.5 % |
AC Current | 1.4 A/115VAC 0.85 A/230VAC | |||||
Inrush Current | Cold start 50A/230VAC | |||||
Leakage Current | < 0.75 mA / 240VAC | |||||
PROTECTION | ||||||
Over L oad | 1 10 ~ 1 50 % rated output power | |||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
Over Voltage | 5.75 ~ 6.75 V | 13.8 ~ 16.2V | 18 .75 ~21 .75 V | 2 8.8 ~ 3 3.6 V | 41.4~4 8 . 6 V | 5 5.2 ~ 6 4.8 V |
Protection type: shut down o/p voltage, re-power on to recover | ||||||
ENVIRONMENT | ||||||
Working Temp. | - 3 0 ~ + 7 0ºC (Refer to " derating curve " ) | |||||
Working Humidity | 20 ~ 90% RH non-condensing | |||||
Storage Temp., Humidity | - 4 0 ~ +85ºC, 10 ~ 95% RH | |||||
Temp. Coefficient | ±0.03%/ºC (0 ~ 50 ºC) | |||||
Vibration | 10 ~ 500Hz, 5 G 10min./1cycle, 60min. each along X, Y, Z axes | |||||
SAFETY & EMC | ||||||
Safety Standards | UL60950-1 , TUV EN60950-1, EN60335-1/-2-16, CCC GB4943 approved | |||||
Withstand Voltage | I/P-O/P:3 .75 KVAC I/P-FG: 2 KVAC O/P-FG: 1.2 5KVAC | |||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH | |||||
EMC Emission | Compliance to EN55022(CISPR22), GB9254 CLASS B, EN55014 EN 61000-3-2,-3 | |||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), heavy industry level, criteria A | |||||
OTHERS | ||||||
Dimension | 99 * 82 * 3 0 mm (L*W*H) | |||||
Weight | 0.3 Kg | |||||
Packing | 45 pcs/ carton /14.5kg/0.77CUFT | |||||
NOTE | ||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |