Model
|
|
S-25-5
|
S-25-12
|
S-25-15
|
S-25-24
|
|
Output
|
DC output Voltage
|
5V
|
12V
|
15V
|
24V
|
|
Voltage tolerance
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Rated Current
|
5A
|
2.1A
|
1.7A
|
1.1A
|
|
Related Power
|
25w
|
25w
|
25w
|
25w
|
|
Wave&Noise
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
|
Adjustable range for DC Voltage
|
±10%
|
±10%
|
±10%
|
±10%
|
|
Set up,rise,hold up time
|
200ms 100ms 30ms
|
|
Input
|
Voltage Range
|
85 ~132VAC 170-264VAC 47-63HZ 240-370VDC
|
|
Input Current
|
0.5A/115VAC 0.25A/230VAC
|
|
Efficiency
|
68%
|
68%
|
68%
|
72%
|
|
AC inrush current
|
Cold start current 15A/115V 30A /230VAC
|
|
Leakage current
|
<0.5mA/240VAC
|
|
Protection
|
Overload
|
Related output power 105-150% start overload protection
|
|
Protection type: cutoff output, recovery after restart power
|
|
Over voltage
|
5.75V-6.75V
|
13.8V-16.2V
|
17.2V-20.2V
|
27.6V-32.4V
|
|
Hiccup mode,recovers automatically after fault condition
|
|
Environment
|
Working temp humidity
|
-10~+60°C 20%~90%RH
|
|
Stor temp, humidity
|
-20~+85°C 20%~90%RH Non-condensing
|
|
Safety
|
Withstand voltage
|
I/P-O/P:1.5KVAC 1min
|
|
I/P-FG:1.5KVAC 1min
|
|
O/P-FG:0.5KVAC 1min
|
|
Standard
|
Safety standard
|
Fit UL1012
|
|
Refer
|
Design refer to GB4943,UL60950,EN60950
|
|
EMC standard
|
Design refer to GB9254,EN55022 Class A
|
|
Size
|
size
|
L99*W97*H35mm
|
|
Package
|
0.3kg, 60 pcs/18kg
|
|
Note:1.All parameters not specially mentioned are measured at 230VAC input, related load and 25 f ambient temperature.2.Wave&noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.3.Tolerance: includes set up tolerance, line regulation and load regulation.
|