Company Profile
Jiangsu Dongfeng Cable Co.,Ltd(Originally Wuxi Dongfeng Factory )was founded in 1988,which is an high-tech private enterprise with collection of research,development and production of various wires and cables.The registered capital is 308 million RMB,total asset is 1810 million RMB.Factory area covers 160 thousand square meters,of which construction area is 120 thousand square meters.The corporation owns a Technology Center of Jiangsu Province Level.
In recent years,the enterprise was granted by government as High Technology Enterprise,Famous Enterprise of Jiangsu Province,Quality Faithful Enterprise,Advanced Enterprise of Wuxi City,Double Civilization Enterprise,AAA Class Credit Enterprise,Enterprise of Observing Contracts And Keeping Promise. Wires and cables of YUNFENG trademark scored many honors,such as Customer Satisfied Products In China,Famous Brand Products Of Jiangsu Province,Famous Brand Of China.The corporation is praised by customers in quality,service and reputation continually for many years,and it was awarded as Customer Satisfied Enterprise In Service And Integrity by China Consumer Protection Foundation,now it become one of important enterprise in wires and cables industry.
Main products of the corporation are :500Kv extra high voltage cable,220 and 110kV and 60kV high voltage power cable,XLPE insulated power cable for rated voltage from 1kV to 35kV,PVC insulated power cable,aerial insulation cable,aerial insulation cable,cables for electrical equipments ,low-smoke halogen-free flame retardant cable,fire proof cable,fire proof cable,general rubber cable,mineral cable,welding cable,control cable,AAC and ACSR,etc.
The company adhere to scientific and technological progress as the motive,ongoing technical transformation ,it now owns 6 production lines of international advanced level for middle and high and extra high voltage cables,which includes a VCV line for 500kV and below power cables made by TROESTER corporation in Germany,and a CCV line for 220kV and below power cables made by MAILLEFER corporation in Finland,each line is configured with eccentricity measurement on line made by SIKORA corporation in Germany.Test equipments for high voltage and partial discharge is 700kV AC resonant test system made by Phenix corporation in USA,and the corporation has over 300 of other main production machines and over 200 of test equipments ,all are first rate in China or in the world.The production ability is 2 million kilometers a year ,the cables can be produced according to national and international standard,or according to customer's requirements.The enterprise has established more than 150 sales corporation in main cities in China,the products can meet the requirements of sectors in power, communication ,airline,railway,automobile,household electrical appliances,oil.chemistry,mine and metallurgy,almost covers all sectors.In recent years,the cables of the corporation is used in many important projects and gained praises,such as Hada high speed railway,Ninghang high speed railway,number 5 lines of Shenzhen subway,Jinqi high speed railway,Qingdao gulf bridge,Beijing Workers' Gymnasium,National urban and rural power grid renovation.110kV cables was used in grid project of inner Mongolia,Guangxi,Chongqing,Sichuan and big steel corporation,Chemistry corporation.The cables work stably and user's feedback is good.
Quality is life of an enterprise,what we are looking for is not only qualified but also is excellent.Jiangsu Dongfeng Cable has impeccable quality assurance system,established quality assurance institutions of technology center and quality test center.The corporation gained ISO9001 certificate,ISO 14001certificate,GB/T28001 certificate.In the moment of hugely developing electricity in our country,the corporation will use the opportunity and its own advantage to meet the requipment of the market and strive to build innovative companies,it will service for the new and old customers by first rate products.
Code | : | BV, H07V-U, NYA |
Standards | : | 227IEC01, BS 6004, VDE0281-3 |
Construction | : | 1- Solid Copper Conductor |
2- PVC insulation | ||
Application | : | Preferably for installation indoors, in cable ducts and in industrial plants or switching stations, |
under ground installation. | ||
Technical Data | : | Max. operating temperature 70 ºC |
Short circuit temperature 160 ºC |
Nominal Cross
Section |
W
ire
Diameter |
Thickness of
insulation |
Mean overall
diameter |
Conductor DC
resistance at 20 ºC |
Approx.
Total Weight |
Max. Current
Carrying Capacity at 30 ºC |
||
mm 2 | No. ×mm | mm | min | max | Ù /km | kg/km | Pip A | Air A |
1.5 | 1.35 | 0.7 | 2.6 | 3.2 | 12.1 | 19 | 16 | 24 |
2.5 | 1.73 | 0.8 | 3.2 | 3.9 | 7.41 | 29 | 20 | 32 |
4 | 2.19 | 0.8 | 3.6 | 4.4 | 4.61 | 42 | 26 | 42 |
6 | 2.68 | 0.8 | 4.1 | 5.0 | 3.08 | 62 | 35 | 55 |
10 | 3.50 | 1.0 | 5.3 | 6.4 | 1.83 | 110 | 46 | 75 |
Code | : | H07V-R, NYA |
Standard | : | IEC 227, BS 6004,VDE 0281 |
Construction | : | 1- Stranded Copper Conductor |
2- PVC Insulation | ||
Application | : | Preferably for installation indoors. in cable ducts and in industrial plants or |
switching stations. under ground installation. | ||
Technical Data | : | Max. operating temperature 70 ºC |
Short circuit temperature 160 ºC |
Nominal
Cross Section |
Number of
wires and Dia. |
Thickness of
insulation |
Mean overall
diameter |
Conductor DC
resistance at 20 ºC |
Approx.
Total Weight |
Max. Current
Carrying Capacity at 30 ºC |
||
mm 2 | No. × mm | mm | min | max | Ù/km | Kg/km | Pip A | Air A |
1.5 | 7×0.51 | 0.7 | 2.7 | 3.3 | 12.1 | 22.0 | 16 | 25 |
2.5 | 7×0.66 | 0.8 | 3.3 | 4.0 | 7.41 | 36.0 | 20 | 34 |
4 | 7×0.83 | 0.8 | 3.8 | 4.6 | 4.61 | 52.0 | 26 | 45 |
6 | 7×1.02 | 0.8 | 4.3 | 5.2 | 3.08 | 74.0 | 35 | 57 |
10 | 7×1.32 | 1.0 | 5.6 | 6.7 | 1.83 | 110 | 46 | 75 |
16 | 7×1.68 | 1.0 | 6.4 | 7.8 | 1.15 | 170 | 62 | 100 |
25 | 7×2.20 | 1.2 | 8.1 | 9.7 | 0.727 | 265 | 82 | 130 |
35 | 7×2.55 | 1.2 | 9.0 | 10.9 | 0.524 | 360 | 100 | 160 |
50 | 7×3.00 | 1.4 | 10.6 | 12.8 | 0.387 | 501 | 120 | 200 |
Code | : | RV,H07V-K, NYAF |
Standard | : | IEC 227, VDE 0281, BS 6004 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC Insulation | ||
Application | : | For protected installation in equipment and lighting fitting. |
Also for in conduit, on and under plaster | ||
Technical Data | : | Max. operating temperature 70 ºC |
Short circuit temperature 160 ºC |
Nominal
Cross Section |
Number of
wires and Dia. |
Thickness of
insulation |
Mean overall
diameter |
Conductor DC
resistance at 20 ºC |
Approx.
Total Weight |
Max. Current
Carrying Capacity at 30 ºC |
||
mm 2 | No. × mm | mm | min | max | Ù/km | Kg/km | Pip A | Air A |
1.5 | 27×0.25 | 0.7 | 2.8 | 3.4 | 13.3 | 21.0 | 15 | 24 |
2.5 | 45×0.25 | 0.8 | 3.4 | 4.1 | 7.98 | 32.0 | 20 | 32 |
4 | 50×0.30 | 0.8 | 3.9 | 4.8 | 4.95 | 48.0 | 25 | 42 |
6 | 75×0.30 | 0.8 | 4.4 | 5.3 | 3.30 | 68.0 | 33 | 54 |
10 | 73×0.40 | 1.0 | 5.7 | 6.8 | 1.91 | 113 | 45 | 73 |
16 | 119×0.40 | 1.0 | 6.7 | 8.1 | 1.21 | 174 | 61 | 98 |
25 | 182×0.40 | 1.2 | 8.4 | 10.2 | 0.780 | 282 | 83 | 129 |
35 | 252×0.40 | 1.2 | 9.7 | 11.7 | 0.554 | 378 | 103 | 158 |
50 | 364×0.40 | 1.4 | 11.5 | 13.9 | 0.386 | 543 | 120 | 198 |
Code | : | H05VV-F, RVV |
Standard | : | IEC 227, VDE 0281, BS 6500 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC insulation. 3- PVC Filling. 4- PVC Outer Sheath | ||
Application | : | For household appliances under medium mechanical stress-also in damp and wet areas |
Technical Data | : | Max. operating temperature 70 ºC |
Short circuit temperature 160 ºC |
Nominal
Cross Section |
Number
and Dia. |
Thickness
of insulation |
Thickness
of Sheath |
Mean overall diameter |
Conductor DC
resistance at 20 ºC |
Approx.
Total Weight |
Max. Current
Carrying Capacity at 30 ºC |
|
No | No. ×mm | mm | Mm | min | max | Ù /km | Kg/km | Air A |
2×0.75 | 22×0.20 | 0.6 | 0.8 | 5.7 | 7.2 | 26.0 | 57.1 | 8 |
2×1 | 30×0.20 | 0.6 | 0.8 | 5.9 | 7.5 | 19.5 | 64.0 | 12 |
2×1.5 | 27×0.25 | 0.7 | 0.8 | 6.8 | 8.6 | 13.3 | 91.0 | 18 |
2×2.5 | 45×0.25 | 0.8 | 1.0 | 8.4 | 10.6 | 7.98 | 135 | 26 |
2×4 | 50×0.30 | 0.8 | 1.1 | 9.7 | 12.1 | 4.95 | 189 | 32 |
2×6 | 75×0.30 | 0.8 | 1.1 | 11.8 | 13.1 | 3.30 | 274 | 42 |
2×10 | 73×0.40 | 0.9 | 1.2 | 14.6 | 15.8 | 1.91 | 422 | 70 |
3×0.75 | 22×0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 26.0 | 68.1 | 8 |
3×1 | 30×0.20 | 0.6 | 0.8 | 6.3 | 8.0 | 19.5 | 77.1 | 12 |
3×1.5 | 27×0.25 | 0.7 | 0.9 | 7.4 | 9.4 | 13.3 | 109 | 18 |
3×2.5 | 45×0.25 | 0.8 | 1.0 | 9.2 | 11.4 | 7.98 | 169 | 26 |
3×4 | 50×0.30 | 0.8 | 1.1 | 10.5 | 13.1 | 4.95 | 238 | 32 |
3×6 | 75×0.30 | 0.8 | 1.1 | 12.5 | 14.2 | 3.30 | 343 | 42 |
3×10 | 73×0.40 | 0.9 | 1.2 | 15.8 | 17.2 | 1.91 | 538 | 70 |
4×0.75 | 22×0.20 | 0.6 | 0.8 | 6.6 | 8.3 | 26.0 | 85.2 | 8 |
4×1 | 30×0.20 | 0.6 | 0.8 | 7.1 | 9.0 | 19.5 | 98.0 | 12 |
4×1.5 | 27×0.25 | 0.7 | 0.8 | 8.4 | 10.5 | 13.3 | 145 | 18 |
4×2.5 | 45×0.25 | 0.8 | 1.1 | 11.0 | 12.5 | 7.98 | 213 | 26 |
4×4 | 50×0.30 | 0.8 | 1.2 | 11.5 | 14.3 | 4.95 | 306 | 32 |
4×6 | 75×0.30 | 0.8 | 1.3 | 13.6 | 15.2 | 3.30 | 427 | 42 |
4×10 | 73×0.40 | 0.9 | 1.4 | 17.2 | 18.3 | 1.91 | 674 | 70 |
4×16 | 119×0.40 | 0.9 | 1.5 | 19.4 | 20.8 | 1.21 | 972 | 80 |
5×0.75 | 22×0.20 | 0.6 | 0.8 | 7.4 | 9.3 | 26.0 | 101 | 8 |
5×1 | 30×0.20 | 0.6 | 0.9 | 7.8 | 9.8 | 19.5 | 125 | 12 |
5×1.5 | 27×0.25 | 0.7 | 1.1 | 9.3 | 11.6 | 13.3 | 176 | 18 |
5×2.5 | 45×0.25 | 0.8 | 1.2 | 11.2 | 13.9 | 7.98 | 261 | 26 |
5×4 | 50×0.30 | 0.8 | 1.3 | 13.0 | 16.1 | 4.95 | 375 | 32 |
5×6 | 75×0.30 | 0.8 | 1.4 | 15.6 | 16.8 | 3.30 | 524 | 42 |
5×10 | 73×0.40 | 0.9 | 1.5 | 18.2 | 20.3 | 1.91 | 831 | 70 |
5×16 | 119×0.40 | 0.9 | 1.6 | 22.3 | 23.2 | 1.21 | 1170 | 80 |
Code | : | H05VVH2-F |
Standard | : | TS 9760, IEC 227, VDE 0281,BS 6500 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC insulation | ||
3- PVC outer sheath | ||
Application | : | In dry. damp and wet locations as flexible connecting cables for light mechanical stresses. |
It is used for hand tools and house hold appliances with flat shape. | ||
Technical Data | : | Max. operating temperature 70 ºC |
Short circuit temperature 160 ºC |
Num. of Cores
and Nominal Cross Section |
Number
and Dia. |
Thickness of
insulation |
Approx.
OD |
Conductor
DC resistance at 20 ºC |
Approx.
Total Weight |
Max. Current
Carrying Capacity at 30 ºC |
||
No×mm 2 | No. ×mm | min | max | max.mm | Ù /km | Kg/km | Pip A | Air A |
2 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 4.00 × 6.40 | 26.0 | 37.0 | - | 13 |
2 × 1 | 30 × 0.20 | 0.6 | 0.8 | 4.10 × 6.60 | 19.5 | 61.1 | 12 | 16 |
2 × 1.5 | 27 × 0.25 | 0.7 | 0.8 | 4.60 × 7.60 | 13.3 | 85.0 | 16 | 20 |
2 × 2.5 | 45 × 0.25 | 0.8 | 1.0 | 5.70 × 9.40 | 7.98 | 128 | 21 | 27 |
2 × 4 | 50 × 0.30 | 0.8 | 1.1 | 6.40 × 10.6 | 4.95 | 185 | 27 | 36 |
3 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 4.00 × 8.80 | 26.0 | 65.0 | - | 13 |
3 × 1 | 30 × 0.20 | 0.6 | 0.8 | 4.10 × 9.10 | 19.5 | 77.0 | 12 | 16 |
3 × 1.5 | 27 × 0.25 | 0.7 | 0.9 | 4.70 × 10.50 | 13.3 | 104 | 16 | 20 |
3 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 5.90 × 13.30 | 7.98 | 159 | 21 | 27 |
3 × 4 | 50 × 0.30 | 0.8 | 1.2 | 6.60 × 15.60 | 4.95 | 228 | 27 | 36 |
Code | : | H05V2-K |
Standard | : | TS 9758, IEC 227, VDE 0281, BS 6004 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC insulation | ||
Application | : | For protected installation in equipment and lighting fitting. |
Also for in conduit. on and under plaster . | ||
Technical Data | : | Max. operating temperature 90 ºC |
Short circuit temperature 160 ºC |
Nominal
Cross Section |
Number
and Dia. |
Thickness
of insulation |
Mean
overall diameter |
Conductor DC
resistance at 20 ºC |
Approx. Total
Weight |
Max. Current Carrying
Capacity at 30 ºC |
||
mm 2 | No. ×mm | mm | min | max | Ù /km | Kg/km | Pip A | Air A |
0.5 | 15 × 0.20 | 0.6 | 2.1 | 2.5 | 39.0 | 10.0 | - | - |
0.75 | 22 × 0.20 | 0.6 | 2.2 | 2.7 | 26.0 | 12.0 | - | 16 |
1 | 30 × 0.20 | 0.6 | 2.4 | 2.8 | 19.5 | 15.0 | 12 | 20 |
Code | : | H07V2-K |
Standard | : | TS 9758, IEC 227, VDE 0281, BS 6004 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC insulation | ||
Application | : | For protected installation in equipment and lighting fitting. |
Also for in conduit. on and under plaster . | ||
Technical Data | : | Max. operating temperature 90 ºC |
Short circuit temperature 160 ºC |
Nominal
Cross Section |
Number
and Dia. |
Thickness of
insulation |
Mean overall
diameter |
Conductor DC
resistance at 20 ºC |
Approx.
Total Weight |
Max. Current
Carrying Capacity at 30 ºC |
||
mm 2 | No. ×mm | mm | min | max | Ù /km | Kg/km | Pip A | Air A |
1.5 | 27 × 0.25 | 0.7 | 2.8 | 3.4 | 13.3 | 21.0 | 15 | 24 |
2.5 | 45 × 0.25 | 0.8 | 3.4 | 4.1 | 7.98 | 32.0 | 20 | 32 |
4 | 50 × 0.30 | 0.8 | 3.9 | 4.8 | 4.95 | 48.0 | 25 | 42 |
6 | 75 × 0.30 | 0.8 | 4.4 | 5.3 | 3.30 | 68.0 | 33 | 54 |
10 | 73 × 0.40 | 1.0 | 5.7 | 6.8 | 1.91 | 113 | 45 | 73 |
16 | 119 × 0.40 | 1.0 | 6.7 | 8.1 | 1.21 | 174 | 61 | 98 |
25 | 182 × 0.40 | 1.2 | 8.4 | 10.2 | 0.780 | 282 | 83 | 129 |
35 | 252 × 0.40 | 1.2 | 9.7 | 11.7 | 0.554 | 378 | 103 | 158 |
50 | 364 × 0.40 | 1.4 | 11.5 | 13.9 | 0.386 | 543 | 132 | 198 |
Code | : | H05V2V2-F |
Standard | : | TS 9760, IEC 227, VDE 0281, BS 6500 |
Construction | : | 1- Flexible Copper Conductor |
2- PVC insulation | ||
3- PVC outer sheath | ||
Application | : | In dry. damp and wet locations as flexible connecting cables for light mechanical |
stresses. It is used for hand tools. heat tools and house hold appliances with flat shape. | ||
Technical Data | : | Max. operating temperature 90 ºC |
Short circuit temperature 160 ºC |
Num. of Cores and
Nominal Cross Section |
Number
and Dia. |
Thickness of
insulation |
Thickness
of Sheath |
Mean overall
diameter |
Conductor DC
resistance at 20 ºC |
Approx.
Total Weight |
Max. Current
Carrying Capacity at 30 ºC |
|
No ×mm 2 | mm | mm | min | max | Ù /km | Kg/km | Air A | |
2 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 5.7 | 7.2 | 26.0 | 57.0 | 8 |
2 × 1 | 30 × 0.20 | 0.6 | 0.8 | 5.9 | 7.5 | 19.5 | 64.1 | 12 |
2 × 1.5 | 27 × 0.25 | 0.7 | 0.8 | 6.8 | 8.6 | 13.3 | 91.0 | 18 |
2 × 2.5 | 45 × 0.25 | 0.8 | 1.0 | 8.4 | 10.6 | 7.98 | 135 | 26 |
2 × 4 | 50 × 0.30 | 0.8 | 1.1 | 9.7 | 12.1 | 4.95 | 189 | 32 |
2 × 6 | 75 × 0.30 | 0.8 | 1.1 | 11.8 | 13.1 | 3.30 | 274 | 42 |
2 × 10 | 73 × 0.40 | 0.9 | 1.2 | 14.6 | 15.8 | 1.91 | 422 | 70 |
3 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 26.0 | 68.1 | 8 |
3 × 1 | 30 × 0.20 | 0.6 | 0.8 | 6.3 | 8.0 | 19.5 | 77.0 | 12 |
3 × 1.5 | 27 × 0.25 | 0.7 | 0.9 | 7.4 | 9.4 | 13.3 | 109 | 18 |
3 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 9.2 | 11.4 | 7.98 | 169 | 26 |
3 × 4 | 50 × 0.30 | 0.8 | 1.2 | 10.5 | 13.1 | 4.95 | 238 | 32 |
3 × 6 | 75 × 0.30 | 0.8 | 1.1 | 12.5 | 14.2 | 3.30 | 343 | 42 |
3 × 10 | 73 × 0.40 | 0.9 | 1.2 | 15.8 | 17.2 | 1.91 | 538 | 70 |
4 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 6.6 | 8.3 | 26.0 | 85.0 | 8 |
4 × 1 | 30 × 0.20 | 0.6 | 0.8 | 7.1 | 9.0 | 19.5 | 98.0 | 12 |
4 × 1.5 | 27 × 0.25 | 0.7 | 0.8 | 8.4 | 10.5 | 13.3 | 145 | 18 |
4 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 11 | 12.5 | 7.98 | 213 | 26 |
4 × 4 | 50 × 0.30 | 0.8 | 1.2 | 11.5 | 14.3 | 4.95 | 306 | 32 |
4 × 6 | 75 × 0.30 | 0.8 | 1.3 | 13.6 | 15.2 | 3.30 | 427 | 42 |
4 × 10 | 73 × 0.40 | 0.9 | 1.4 | 17.2 | 18.3 | 1.91 | 674 | 70 |
4 × 16 | 119 × 0.40 | 0.9 | 1.5 | 19.4 | 20.8 | 1.21 | 972 | 80 |
5 × 0.75 | 22 × 0.20 | 0.6 | 0.8 | 7.4 | 9.3 | 26.0 | 101 | 8 |
5 × 1 | 30 × 0.20 | 0.6 | 0.9 | 7.8 | 9.8 | 19.5 | 125 | 12 |
5 × 1.5 | 27 × 0.25 | 0.7 | 1.0 | 9.3 | 11.6 | 13.3 | 176 | 18 |
5 × 2.5 | 45 × 0.25 | 0.8 | 1.1 | 11.2 | 13.9 | 7.98 | 261 | 26 |
5 × 4 | 50 × 0.30 | 0.8 | 1.3 | 13.0 | 16.1 | 4.95 | 375 | 32 |
5 × 6 | 75 × 0.30 | 0.8 | 1.4 | 15.6 | 16.8 | 3.30 | 524 | 42 |
5 × 10 | 73 × 0.40 | 0.9 | 1.5 | 18.2 | 20.3 | 1.91 | 831 | 70 |
Code | : | NVV |
Standard | : | TS 9759 HD 21,4 S2, VDE 0250-204, BS 6004 |
Construction | : | 1- Solid or Stranded Copper Conductor |
2- PVC insulation 3- PVC Filling 4- PVC outer sheath | ||
Application | : | Fixed wiring in dry and damp premises, in conduits. on or under plaster and on |
insulators over plaster, switching. | ||
Technical Data | : | Max. operating temperature 70 ºC Short circuit temperature 160 ºC |
Num. of
Cores and Nominal Cross Section |
Number
and Dia. |
Thickness
of insulation |
Thickness
of Sheath |
Mean overall diameter |
Conductor
DC resistance at 20 ºC |
Approx.
Total Weight |
Max. Current
Carrying Capacity at 30 ºC |
|
No ×mm 2 | mm | mm | mm | min | max | Ù /km | Kg/km | Air A |
2 × 1.5 | 1.35 | 0.7 | 1.2 | 8.4 | 10.0 | 12.1 | 108 | 22 |
2 × 2.5 | 1.73 | 0.8 | 1.2 | 9.6 | 11.5 | 7.41 | 148 | 30 |
2 × 4 | 2.19 | 0.8 | 1.2 | 10.5 | 12.5 | 4.61 | 194 | 40 |
2 × 6 | 2.68 | 0.8 | 1.2 | 11.5 | 13.5 | 3.08 | 250 | 51 |
2 × 10 | 7 × 1.32 | 1.0 | 1.4 | 14.5 | 16.5 | 1.83 | 427 | 70 |
2 × 16 | 7 × 1.66 | 1.0 | 1.4 | 16.5 | 20.0 | 1.15 | 604 | 94 |
3 × 1.5 | 1.35 | 0.7 | 1.2 | 8.8 | 10.5 | 12.1 | 128 | 22 |
3 × 2.5 | 1.73 | 0.8 | 1.2 | 10.0 | 12.0 | 7.41 | 179 | 30 |
3 × 4 | 2.19 | 0.8 | 1.2 | 11.0 | 13.0 | 4.61 | 239 | 40 |
3 × 6 | 2.68 | 0.8 | 1.2 | 12.5 | 14.5 | 3.08 | 319 | 51 |
3 × 10 | 7 × 1.32 | 1.0 | 1.4 | 15.5 | 17.5 | 1.83 | 535 | 70 |
3 × 16 | 7 × 1.66 | 1.0 | 1.4 | 18.0 | 21.5 | 1.15 | 769 | 94 |
4 × 1.5 | 1.35 | 0.7 | 1.2 | 9.6 | 11.5 | 12.1 | 154 | 18.5 |
4 × 2.5 | 1.73 | 0.8 | 1.2 | 11.0 | 13.0 | 7.41 | 219 | 25 |
4 × 4 | 2.19 | 0.8 | 1.2 | 12.0 | 14.5 | 4.61 | 301 | 34 |
4 × 6 | 2.68 | 0.8 | 1.2 | 14.0 | 16.0 | 3.08 | 399 | 43 |
4 × 10 | 7 × 1.32 | 1.0 | 1.4 | 16.5 | 19.0 | 1.83 | 669 | 60 |
4 × 16 | 7 × 1.66 | 1.0 | 1.4 | 20.0 | 23.5 | 1.15 | 970 | 80 |
5 × 1.5 | 1.35 | 0.7 | 1.2 | 10.0 | 12.0 | 12.1 | 181 | 15.5 |
5 × 2.5 | 1.73 | 0.8 | 1.2 | 12.0 | 14.5 | 7.41 | 262 | 22 |
5 × 4 | 2.19 | 0.8 | 1.2 | 13.5 | 16.0 | 4.61 | 364 | 31 |
5 × 6 | 2.68 | 0.8 | 1.2 | 15.0 | 17.5 | 3.08 | 483 | 40 |
5 × 10 | 7 × 1.32 | 1.0 | 1.4 | 18.0 | 21.0 | 1.83 | 828 | 56.5 |
Code | : | Flat Cables |
Standard | : | TS 9760, IEC 227, VDE 0281, BS 6500 |
Construction | : | 1- Solid Copper Conductor |
2- PVC insulation | ||
3- PVC outer sheath | ||
Application | : | Preferably for installation indoors, in cable ducts and in industrial plants or switching |
stations, under ground installation, with additional protection where mechanical damage | ||
is unexpected. | ||
Technical Data | : | Max. operating temperature 70 ºC |
Short circuit temperature 160 ºC |
Num. of Cores
and Nominal Cross Section |
Number
and Dia. |
Thickness of
insulation |
Thickness of
Sheath |
Conductor DC
resistance at 20 ºC |
Approx.
Total Weight |
Max. Current
Carrying Capacity at 3 0 ºC |
|
No. ×mm 2 | No. ×mm | mm | mm | Ù /km | Kg/km | Pipe A | Air A |
2 × 1 | 1.1 | 0.6 | 0.8 | 18.1 | 50.0 | - | 19 |
2 × 1.5 | 1.35 | 0.7 | 0.8 | 12.1 | 66.0 | 32 | 20 |
2 × 2.5 | 1.73 | 0.8 | 1.0 | 7.41 | 104 | 42 | 20 |
2 × 4 | 2.19 | 0.8 | 1.1 | 4.61 | 143 | 54 | 20 |
3 × 1 | 1.1 | 0.6 | 0.8 | 18.1 | 73.0 | - | 20 |
3 × 1.5 | 1.35 | 0.7 | 0.9 | 12.1 | 101 | 26 | 20 |
3 × 2.5 | 1.73 | 0.8 | 1.1 | 7.41 | 158 | 34 | 20 |
3 × 4 | 2.19 | 0.8 | 1.2 | 4.61 | 216 | 44 | 20 |
Code | : | FLAT TWIN& THREE CORE CABLES |
Standard | : | BS6004 |
Construction | : | 1- Stranded Copper Conductor |
2- PVC insulation | ||
3- PVC outer sheath | ||
Application | : | These Cables are used in dry or damp locations for fixed installation. |
Suitable for installation in walls or embedded in plaster. | ||
Technical Data | : | Max. operating temperature 70 ºC |
Num. of Cores
and Nominal Cross Section |
Number
and Dia. |
Thickness of
insulation |
Thickness of
Sheath |
Conductor DC
resistance at 20 ºC |
Approx.
Total Weight |
Max. Current
Carrying Capacity at 30 ºC |
|
No ×mm 2 | No. ×mm | mm | mm | Ù /km | Kg/km | Pipe A | Air A |
2 × 1.5 | 7 × 0.51 | 0.7 | 0.9 | 12.1 | 76..0 | 32 | 20 |
2 × 2.5 | 7 × 0.66 | 0.8 | 1.0 | 7.41 | 110 | 42 | 27 |
2 × 4 | 7 × 0.83 | 0.8 | 1.0 | 4.61 | 148 | 54 | 37 |
3 × 1.5 | 7 × 0.51 | 0.7 | 0.9 | 12.1 | 102 | 26 | 18 |
3 × 2.5 | 7 × 0.66 | 0.8 | 1.0 | 7.41 | 152 | 34 | 25 |
3 × 4 | 7 × 0.83 | 0.8 | 1.1 | 4.61 | 224 | 44 | 34 |
Packing
Our workshop