Inscinstech Protein Purification System (Unique AutoPure150-M604) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP

Model NO.
Unique AutoPure150-M604
Chromatography Type
Liquid Chromatography
Pressure
0-5MPa
Wavelength Detector
280nm Fix Wavelength Detector
Including
5ml Mixer
Flowrate
0.001-150.000ml/Min
Piston Pump
Metering Type
Transport Package
Flight Case
Specification
LxWxH: 450mmx400x480
Trademark
Inscinstech
Origin
Suzhou
Reference Price
$ 40,320.00 - 41,220.00

Product Description

Inscinstech Protein Purification System (Unique AutoPure150-M604) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP Inscinstech Protein Purification System (Unique AutoPure150-M604) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
Model Unique AutoPure150-L1
Article No. 04-004 -002-150
Description
1.Piston Pump  
1.1 Binary gradient biological inert infusion pump
*Flowrate:
Range: 0.01-150.000ml/min
Flowrate accuracy: 1.2%
Flowrate precision: 0.5%
*Pressure: 0-5MPa
*Dynamic mixer: 2ml, panel mounted, easy to replace
2. Automatic Sampling Valve  
2.1 Automatic sampling valve, which can be reversely controlled
by software and supports Load/Inject/Waste
2.2 5ml loop
3. 280nm Fixed Wavelength Detector  
3.1 280 nm imported LED detector, life: >8000 Hr
3.2 Noise: ±2×10 -5 AU
3.3 2mm flow cell
4. Conductivity Detector
4.1 Range: 0.000-999.99 mS/cm
4.2 Accuracy: ±0.02mS/cm or ±2%
5. Chromatography Workstation  
(including branded computer, software and communication
module, chromatography workstation software)

 
Model Unique AutoPure150-M402
Article No. 04-004 -002-152
Description
1.Piston Pump
1.1 Binary gradient biological inert infusion pump
*Flowrate:
Range: 0.01-150.000ml/min
Flowrate accuracy: 1.2%
Flowrate precision: 0.5%
*Pressure: 0-5MPa
*Dynamic mixer: 2ml, panel mounted, easy to replace
2. Automatic Sampling Valve  
2.1 Automatic sampling valve, which can be reversely controlled
by software and supports Load/Inject/Waste
2.2 1ml loop
3. DAD Detector  
3.1 200-400nm import dual-channel DAD detector
3.2 Noise: ±1×10 -4 AU
3.3 2mm flow cell
4. Conductivity Detector  
4.1 Range: 0.001-999.99 mS/cm
4.2 Accuracy: ±0.02mS/cm or ±2%
5. Chromatography Workstation  
(including branded computer, software and communication
module, chromatography workstation software)

 
Inscinstech Protein Purification System (Unique AutoPure150-M604) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP Inscinstech Protein Purification System (Unique AutoPure150-M604) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP Inscinstech Protein Purification System (Unique AutoPure150-M604) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP

 