Lpcb Approved Surface Mounted Independent Smoke Detector Fire Alarm Detector

Model NO.
LZ-1902
Infrared Sensor Probe Type
Standalone Sensor
Infrared Sensor Installation
Ceiling
Combustible Gas Detector Model
Lz-1902
Alarm Indication
Red LED & Buzzer
Ambient Humidity
<=95% R.H
N.W.
89g (Not Incl. Battery)
Installation Way
Ceiling Mounting
Sound Pressure
>=85dB(Around 3m)
Alarm Current
<=30mA
Temperature
0 Degree Centigrade~+40 Degree Centigrade
Sensor Type
Photoelectric
Voltage
DC9V
Transport Package
Carton
Specification
diameter 100*36.7mm
Trademark
detector
Origin
China
HS Code
8531100000
Production Capacity
500000/Month
Reference Price
$ 26.10 - 31.50

Product Description

1. Product Description

The product is smoke detector, it can send out sound and light alarm signal in the early stage of the fire if properly installed and maintained, in that case you   will   have   extra   time   to   control   the   fire   or   to   evacuate at once. This product is designed for household or similar residential application   use.

2. Techinical Data
Model No. LZ-1902
Standard  EN-14604:2005/AC:2008
Voltage DC9V
Standby Current <=10uA
Alarm Current <=3mA
Sensor Type photoelectric
Temperature -10ºC~+40ºC
Ambient Humidity <=95%R.H
Alarm Indication Red LED & Buzzer
Sound Pressure >=85dB(around 3m)
N.W. 89g(not incl. batttery)
Product Size Φ100*36.7mm
Installation Way Ceiling Mounting

3. Installation method

  1. Choose the right installation   placement.
  2. Drill 2 round holes with 5mm diameter on the ceiling. ( Distance between the two holes is 75-80   mm)
  3. Use the enclosed two expansion rubber and plugs into the holes.
  4. Install the mounting bracket of the smoke detector on the ceiling. by using the two screws   enclosed.
  5. Install the smoke detector battery to the mounting bracket. Note: Step 3 and 4 can be ignored if it is mounted on a wooden ceiling.

4. Test Function

  1. Put the 9 V battery into the detector, LED will flash once every 30 seconds and the alarm won't make any sound, which indicating the detector will work in normal standby   condition.
  2. Press the test button and keep for a while, then the smoke detector will flash and 5 seconds later the alarm will emit a sound, when the sounder emits three consecutive sounds, release the test button, the detector will stop alarm within   seconds.
5. Maintenance
  1. It is recommended to press the test button every   week  to check the smoke detector works correctly.
  2. To ensure the sensitivity of the product, clean the surface of the detector with soft brush every   month.
  3. The smoke detector is with fault detection function. When the smoke sensor is short circuited or  disconnected, the detector will automatically detect and send a fault signal. For example alarm will emit a beep between two flashes. When the  battery voltage is  too low, the detector will periodically send out low voltage fault signals. For example LED flashes every 30s and alarm emits a beep, in this case battery should be replaced   accordingly.
Lpcb Approved Surface Mounted Independent Smoke Detector Fire Alarm Detector
Lpcb Approved Surface Mounted Independent Smoke Detector Fire Alarm Detector
Lpcb Approved Surface Mounted Independent Smoke Detector Fire Alarm Detector
Lpcb Approved Surface Mounted Independent Smoke Detector Fire Alarm Detector
Lpcb Approved Surface Mounted Independent Smoke Detector Fire Alarm Detector
Lpcb Approved Surface Mounted Independent Smoke Detector Fire Alarm Detector
Lpcb Approved Surface Mounted Independent Smoke Detector Fire Alarm Detector
Lpcb Approved Surface Mounted Independent Smoke Detector Fire Alarm Detector
Lpcb Approved Surface Mounted Independent Smoke Detector Fire Alarm Detector
Lpcb Approved Surface Mounted Independent Smoke Detector Fire Alarm Detector


 

 

PNEUTEC.IT, 2023