0-50A Input 4-20mA Output AC Leakage Residual Current Sensor

Model NO.
HGLC-AC/DC Series
Material
Plastic
Accuracy Grade
0.5G
Application
Leakage Current Sensor
IP Rating
IP55
Certification
RoHS
Customized
Customized
Bandwidth
AC 50Hz
Withstand Resistance
Voltage Output-5mA Current Output-6V
Temperature Drift
100ppm/Deg.C
Input Power Supply Voltage Range
DC 12V, DC 15V
Storage Temperature
-25-85 Deg.C
Keywords
Leakage Current Sensor
Operating Ambient Temp. Range
-25-80 Deg.C
Response Time
300ms
Rated Output
DC1V, DC2V, DC4V, DC5V, DC 0-20mA, DC 4-20mA
Primary Current
5mA...20mA...50mA...100mA...500mA...800mA...1000mA
Offset Voltage
20mv
Insulation Withstand Voltage
3kv/50Hz,2mA,1min
Accuracy
1%
Linearity
0.5%
Mounting
Screw Fastening Flat Mounting
Transport Package
1kg
Specification
20*15*15cm
Trademark
Siko Instruments
Origin
China
HS Code
9030339000
Production Capacity
999 Units / Weeks
Package Size
25.00cm * 15.00cm * 15.00cm
Package Gross Weight
1.000kg
Reference Price
$ 33.30 - 40.50

Product Description

0-50A Input 4-20mA Output AC Leakage Residual Current Sensor

Model: HGLC-SF-1
Window Diameter: Ø25mm 
Primary Nominal Current: DC 5mA-1000mA

Working Principle: HGLC-SF-1 DC Leakage Current Sensor using the principle of magnetic modulation.
Product Use: Closed loop for isolated measurement of DC milliampere small current. 
Application: Widely used in emerging industries, and field such as electric power, industrial automation, solar photovoltaic...leakage monitoring system etc 

Features:  
* The isolation voltage between primary and secondary is greater than 3000VAC.
* Temperature compensation circuit control, zero drift and accurate measurement.
* Perforated input, unplugging terminals and screw fastening flat mounting.
* Overall size(mm): 70(L)*29(W)*60(H)mm; Aperture: 25mm
* Potting glue has elastic characteristics. Good mechanical properties such as corrosion resistance, aging resistance, and heat resistance.

 
Product Description

0-50A Input 4-20mA Output AC Leakage Residual Current Sensor 0-50A Input 4-20mA Output AC Leakage Residual Current Sensor

Features
01.  4-Bits LED Digital Display.
02.   Switching Points Can Be Set Arbitrarily On Site Between Zero And Full Point .
03.   Pressure Measurement For Gas And Liquid.
04.  PNP Switch Point Setting And Time Delay Setting For Action.
05.  PNP Switch Output And Analog 4-20mA Output Optional.
06.  4-20mA, 0-10V, RS 485 Outputs Available.
07.  2 Switch Output (NPN/PNP) With Load Capacity 1.2A.
08.  M12 Standard Electrial Connection.
09.  Button Adjustment And On-site Setting of Various Parameters Easy To Operate.

0-50A Input 4-20mA Output AC Leakage Residual Current Sensor 0-50A Input 4-20mA Output AC Leakage Residual Current Sensor
Product Parameters

0-50A Input 4-20mA Output AC Leakage Residual Current Sensor

Selection Table

0-50A Input 4-20mA Output AC Leakage Residual Current Sensor

Outline Dimension

0-50A Input 4-20mA Output AC Leakage Residual Current Sensor

Electrical Connection

0-50A Input 4-20mA Output AC Leakage Residual Current Sensor

Company Profile

0-50A Input 4-20mA Output AC Leakage Residual Current Sensor 0-50A Input 4-20mA Output AC Leakage Residual Current Sensor

 